IMC Networks E1, IE-IMCV-T1 operation manual Switch Settings for Switch S3

Page 11

 

 

 

Switch Settings for Switch S3

 

 

 

Reserved

 

 

 

 

 

S3-1: ON

Reserved

 

 

 

 

S3-1: OFF

Reserved

 

 

default

 

Remote Management

 

 

 

 

S3-2: ON

Remote Management Enabled (only at the REMOTE end)

 

 

 

S3-2: OFF

Remote Management Disabled (only at the LOCAL end)

 

default

 

Loopback Selection iVIEW2

 

 

 

 

S3-3: ON

S3-4: ON

None

iVIEW2

default

S 3

S3-3: OFF

S3-4: ON

Fiber Analog Loopback

iVIEW2

 

S3-3: ON

S3-4: OFF

Internal Fiber Loopback

iVIEW2

 

H

S3-3: OFF

S3-4: OFF

Copper Remote Loopback

iVIEW2

 

Monitor/Boost Mode

 

 

 

C

 

 

 

S3-5: ON

S3-6: ON

Normal Operation (No Boost)

 

default

I T

 

S3-5: OFF

S3-6 ON

20 dB

 

 

W

S3-5: ON

S3-6 OFF

26 dB

 

 

S3-5: OFF

S3-6 OFF

32 dB

 

 

S

 

 

Fault Loopback

 

 

 

 

 

 

 

 

 

 

S3-7: ON

Send AIS is sent back toward the fault on the RJ-45 port

iVIEW2

 

 

S3-7: OFF

AIS is only sent toward the fiber on detecting a fault on the

iVIEW2

default

 

 

RJ-45 port

 

 

 

 

Fiber Type

 

 

 

 

 

S3-8: Factory Configured

DO NOT CHANGE

 

 

 

S3-9: Factory Configured

DO NOT CHANGE

 

 

 

S3-10: Factory Configured

DO NOT CHANGE

 

 

8

Image 11
Contents IE-iMcV-T1/E1/J1-LineTerm SFP FCC Radio Frequency Interference Statement WarrantyTable of Contents IE-iMcV-T1/E1/J1-LineTerm in this manual About the IE-iMcV-T1/E1/J1-LineTerm, TP/SFPPage Managed Modules Configuration Control Unmanaged Modules IView² Management SoftwareDIP Switches Switch Settings for Switch S2 DIP Switch Settings S2, S3Switch Settings for Switch S3 SFP FeaturesLoopback Loopback ModesTransmit Data Source Fault LoopbackTransmit LIU Waveshape and Gain Line Build-Out Remote Management T1, E1 and J1 SelectionCopper Port LEDs LED OperationLoopback Testing Installation Troubleshooting General Troubleshooting Pseudorandom Bit Sequence Prbs TestingPin Signal IMC Networks Technical Support SpecificationsFiber Optic Cleaning Guidelines Electrostatic Discharge Precautions Certifications Document Number 50-80104-00 A1