IMC Networks E1, IE-IMCV-T1 operation manual

Page 5
and MediaChassis series.
Installing an iMcV-Module
iMcV-Modules install in IMC Networks’ SNMP manageable iMediaChassis series or in any MediaChassis/IE-MediaChassis series.
To install an iMcV-Module:
1. Remove the blank bracket covering the slot where the module is to be installed by removing the screws on the outside edges of the bracket.
2. Slide the iMcV-Module into the chassis, via the cardguides, until the module is seated securely in the connector.
3. Secure the module to the chassis by tightening the captive screw.
4. Save any “blanks” removed during installation for future use if the configuration requirements change.
NOTE
All modules are hot-swappable
Crossover/Straight-Through Connection
IE-iMcV-T1/E1/J1-LineTerm, TP/SFP comes with an RJ-48 UTP connector that features a push-button switch, located next to the port, for selecting a crossover connection, push-button IN. A straight-through connection is selected when the push-button is OUT. When unsure what type of connection is needed, set the push button to the position that turns the LOS LED off.
Configuration
Proper configuration of the IE-iMcV-T1/E1/J1-LineTerm, TP/SFP is required for maximum performance and reliability. The following sections describe the prerequisites and the configurations available for both managed and unmanaged modules.
Prerequisites
The IE-iMcV-T1/E1/J1-LineTerm, TP/SFP conforms to any T1/E1/J1-based environment. Ensure all of the relevant information about the expected installation environment is available before configuring the module. This information includes:
Line Type T1 or E1
Line Coding used on T1: either AMI or B8ZS
Distance of the copper run for DSX1 lines (655 feet MAX)
2
with SFP Module can be installed in an iMediaChassis
IE-iMcV-T1/E1/J1-LineTerm, TP/SFP
NOTE
Image 5
Contents IE-iMcV-T1/E1/J1-LineTerm SFP FCC Radio Frequency Interference Statement WarrantyTable of Contents IE-iMcV-T1/E1/J1-LineTerm in this manual About the IE-iMcV-T1/E1/J1-LineTerm, TP/SFPPage Managed Modules Configuration Control Unmanaged Modules IView² Management SoftwareDIP Switches Switch Settings for Switch S2 DIP Switch Settings S2, S3Switch Settings for Switch S3 SFP FeaturesLoopback Loopback ModesTransmit Data Source Fault LoopbackTransmit LIU Waveshape and Gain Line Build-Out Remote Management T1, E1 and J1 SelectionCopper Port LEDs LED OperationLoopback Testing Installation Troubleshooting General Troubleshooting Pseudorandom Bit Sequence Prbs TestingPin Signal IMC Networks Technical Support SpecificationsFiber Optic Cleaning Guidelines Electrostatic Discharge Precautions Certifications Document Number 50-80104-00 A1