IMC Networks IE-IMCV-T1 operation manual T1, E1 and J1 Selection, Remote Management

Page 15

T1, E1 and J1 Selection

This switch selects the data rate to use on the copper line. The data rate selections available include the following:

T1/J1 (1.544 Mbps +/- 32 ppm)

E1 (2.048 Mbps +/- 32 ppm)

By default this feature is set to T1.

This feature can be selected only by setting the DIP Switches manually.

Remote Management

A DIP Switch enables or disables the Remote Management mode. By default this feature is Disabled. Remote Management must be enabled on the REMOTE module. This allows all SNMP-configurable features for the REMOTE modules to be configured from the HOST module.

An IE-iMcV-T1/E1/J1-LineTerm w/SFP Module with Configuration Control, configured as a Host, allows an SNMP Management Module in a managed chassis to manage the Remote. All settings are enabled and enforced through the SNMP. The Host keeps a copy of the Remote’s configuration settings.

When the Host unit is in a managed chassis, the Host configures the Remote. This ensures that the Remote’s configuration will not revert to its DIP Switch settings and potentially disrupt traffic. However, if the customer changes the DIP Switch settings on the Remote, the new configuration of the Remote will be saved by the host.

When SNMP management is installed at the Host, the following functions at the Remote are controlled from the Host unit:

Loopback

Line Code

Transmit Data Source

Fault Loopback

NOTE

IE-iMcV-T1/E1/J1-LineTerm, TP/SFP with SFP Module can be installed in an iMediaChassis and MediaChassis series. However, there is no support for the module in the iMediaCenter Series.

12

Image 15
Contents IE-iMcV-T1/E1/J1-LineTerm SFP FCC Radio Frequency Interference Statement WarrantyTable of Contents IE-iMcV-T1/E1/J1-LineTerm in this manual About the IE-iMcV-T1/E1/J1-LineTerm, TP/SFPPage Managed Modules Configuration Control Unmanaged Modules IView² Management SoftwareDIP Switches Switch Settings for Switch S2 DIP Switch Settings S2, S3Switch Settings for Switch S3 SFP FeaturesLoopback Loopback ModesFault Loopback Transmit LIU Waveshape and Gain Line Build-OutTransmit Data Source Remote Management T1, E1 and J1 SelectionCopper Port LEDs LED OperationLoopback Testing Installation Troubleshooting General Troubleshooting Pseudorandom Bit Sequence Prbs TestingPin Signal IMC Networks Technical Support SpecificationsFiber Optic Cleaning Guidelines Electrostatic Discharge Precautions Certifications Document Number 50-80104-00 A1