5.2.3. Failure and Error Messages

These messages will be displayed in the event of a

RAID or disk failure, or an error during a process.

RAID Failure Messages

LCD Display

Message

Message Cleared When...

RAID Fail

The RAID array failed. There are not

A disk is re-installed

enough disks for the RAID array to

 

code: 0

 

operate.

 

 

 

RAID Fail

The RAID array failed. The sequence

The original disk sequence is

of the disks in the array is incorrect.

restored

code: 1 <---->

The current sequence is displayed

 

 

 

 

within the “<---->” space.

 

RAID Fail

The RAID array failed but all original

The RAID array is recreated.

disks are existing after restarting the

 

code: 2

 

unit.

 

 

 

Disk Failure Message

 

 

LCD Display

Message

Message Cleared When...

DISK x Fail

Disk “x” failed.

The failed disk is replaced

 

 

Fan Failure Message

LCD Display

Message

Message Cleared When...

FAN Fail

Fan failure. xxxx rpm = the current

The failed fan is repaired or replaced

speed of the fan

 

xxxx rpm

 

 

 

Page 39