LaCie Biggest Quadra | Using the Biggest Quadra |
User Manual | page 38 |
|
|
■5.2.3. Failure and Error Messages
These messages will be displayed in the event of a
RAID or disk failure, or an error during a process.
RAID Failure Messages
LCD Display | Message | Message Cleared When... | |
RAID Fail | The RAID array failed. There are not | ❖ A disk is | |
enough disks for the RAID array to |
| ||
code: 0 |
| ||
operate. |
| ||
|
| ||
RAID Fail | The RAID array failed. The sequence | ❖ The original disk sequence is | |
of the disks in the array is incorrect. | restored | ||
code: 1 | |||
The current sequence is displayed |
| ||
|
| ||
| within the |
| |
RAID Fail | The RAID array failed but all original | ❖ The RAID array is recreated. | |
disks are existing after restarting the |
| ||
code: 2 |
| ||
unit. |
| ||
|
| ||
Disk Failure Message |
|
| |
LCD Display | Message | Message Cleared When... | |
DISK x Fail | Disk “x” failed. | ❖ The failed disk is replaced | |
|
|
Fan Failure Message
LCD Display | Message | Message Cleared When... |
FAN Fail | Fan failure. xxxx rpm = the current | ❖ The failed fan is repaired or replaced |
speed of the fan |
| |
xxxx rpm |
| |
|
|