Lenovo RS210 manual Integrated management module error messages

Models: RS210

1 244
Download 244 pages 35.96 Kb
Page 38
Image 38
Integrated management module error messages

Integrated management module error messages

The following table describes the IMM error messages and suggested actions to correct the detected problems.

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Message

Severity

Description

Action

 

 

 

 

Numeric sensor Ambient Temp

Error

An upper critical sensor

Reduce the ambient temperature.

going high (upper critical) has

 

going high has asserted.

 

asserted.

 

 

 

 

 

 

 

Numeric sensor Ambient Temp

Error

An upper nonrecoverable

Reduce the ambient temperature.

going high (upper non-recoverable)

 

sensor going high has

 

has asserted.

 

asserted.

 

 

 

 

 

Numeric sensor Planar 3.3V going

Error

A lower critical sensor going

(Trained service technician only)

low (lower critical) has asserted.

 

low has asserted.

Replace the system board.

 

 

 

 

Numeric sensor Planar 3.3V going

Error

An upper critical sensor

(Trained service technician only)

high (upper critical) has asserted.

 

going high has asserted.

Replace the system board.

 

 

 

 

Numeric sensor Planar 5V going low

Error

A lower critical sensor going

(Trained service technician only)

(lower critical) has asserted.

 

low has asserted.

Replace the system board.

 

 

 

 

Numeric sensor Planar 5V going

Error

An upper critical sensor

(Trained service technician only)

high (upper critical) has asserted.

 

going high has asserted.

Replace the system board.

 

 

 

 

Numeric sensor Planar VBAT going

Error

A lower critical sensor going

Replace the 3 V battery.

low (lower critical) has asserted.

 

low has asserted.

 

 

 

 

 

Numeric sensor Fan n Tach going

Error

A lower critical sensor going

1. Reseat the failing fan n, which

low (lower critical) has asserted.

 

low has asserted.

is indicated by a lit LED on

(n = fan number)

 

 

 

 

the system board (see

 

 

 

 

 

 

“System-board LEDs” on

 

 

 

page 112).

 

 

 

2. Replace the failing fan.

 

 

 

(n = fan number)

 

 

 

 

30ThinkServer ThinkServer RS210, Types 6531, 6532, 6533, and 6534: Hardware Maintenance Manual

Page 38
Image 38
Lenovo RS210 manual Integrated management module error messages