vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

vGo to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new device drivers or to submit a request for information.

Error code

Description

Action

 

 

 

 

2018001

PCI Express uncorrected or uncorrected error

1.

Check the riser-card LEDs.

 

 

2.

Reseat all affected adapters and riser cards.

 

 

3.

Update the PCI adapter firmware.

 

 

4.

Remove the adapter from the riser card.

 

 

5.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. Riser card

 

 

 

b. (Trained service technician only) System board

 

 

 

2018002

Option ROM resource allocation failure

Informational message that some devices might not

 

 

be initialized.

 

 

1.

If possible, rearrange the order of the adapters in

 

 

 

the PCI slots to change the load order of the

 

 

 

optional-device ROM code.

 

 

2.

Run the Setup utility, select Startup Options, and

 

 

 

change the boot priority to change the load order

 

 

 

of the optional-device ROM code.

 

 

3.

Run the Setup utility and disable some other

 

 

 

resources, if their functions are not being used, to

 

 

 

make more space available.

 

 

 

a. Select Startup Options → Planar Ethernet

 

 

 

(PXE/DHCP) to disable the integrated

 

 

 

Ethernet controller ROM.

 

 

 

b. Select Advanced Functions → PCI Bus Control

 

 

 

→ PCI ROM Control Execution to disable the

 

 

 

ROM of the adapter in the PCI slots.

 

 

 

c. Select Devices and I/O Ports to disable any of

 

 

 

the integrated devices.

 

 

4.

Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. Each adapter

 

 

 

b. (Trained service technician only) System board

 

 

 

 

3xx0007 (xx

Firmware fault detected, system halted

1.

Recover the server firmware to the latest level.

can be 00 -

 

 

2.

Undo any recent configuration changes, or clear

19)

 

 

 

CMOS memory to restore the settings to the

 

 

 

 

 

 

default values (see Table 6 on page 111).

 

 

3.

Remove any recently installed hardware.

 

 

 

 

Chapter 4. Diagnostics 25

Page 33
Image 33
Lenovo RS210 manual Error code