vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

vGo to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new device drivers or to submit a request for information.

Error code

Description

Action

 

 

 

 

0051003

Uncorrectable DIMM error

1.

If the server failed the POST memory test, reseat

 

 

 

 

 

the DIMMs.

 

 

2.

Remove and replace any DIMM for which the

 

 

 

associated error LED is lit (see “Removing a

 

 

 

memory module” on page 124 and “Installing a

 

 

 

memory module” on page 125).

 

 

3.

Run the Setup utility to enable all the DIMMs.

 

 

4.

Run the DSA Preboot memory test (see“Running

 

 

 

the diagnostic programs” on page 69).

 

 

 

0051006

DIMM mismatch detected

Make sure that the DIMMs match and are installed in

 

 

the correct sequence (see “Installing a memory

 

 

module” on page 125).

 

 

 

 

0051009

No memory detected.

1.

Make sure that the server contains DIMMs.

 

 

 

 

2.

Reseat the DIMMs.

 

 

3.

Install DIMMs in the correct sequence (see

 

 

 

“Installing a memory module” on page 125).

 

 

 

 

005100A

No usable memory detected.

1.

Make sure that the server contains DIMMs.

 

 

 

 

2.

Reseat the DIMMs.

 

 

3.

Install DIMMs in the correct sequence (see

 

 

 

“Installing a memory module” on page 125).

 

 

4.

Clear CMOS memory to re-enable all the memory

 

 

 

connectors (see “System-board switches and

 

 

 

jumpers” on page 111).

 

 

 

 

0058001

PFA threshold exceeded

1.

Update the server firmware to the latest level (see

 

 

 

 

 

“Updating the firmware” on page 212).

 

 

2.

Reseat the DIMMs and run the memory test (see

 

 

 

“Running the diagnostic programs” on page 69).

 

 

3.

Replace the failing DIMM, which is indicated by

 

 

 

a lit LED on the system board.

 

 

 

 