Lenovo RS210 manual Sensor CPU nOverTemp has

Models: RS210

1 244
Download 244 pages 35.96 Kb
Page 41
Image 41
Sensor CPU nOverTemp has

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Sensor CPU nOverTemp has

Error

A sensor has changed to

1.

Make sure that the fans are

transitioned to critical from a less

 

Critical state from a less

 

 

operating, that there are no

severe state.

 

severe state.

 

 

 

obstructions to the airflow,

(n = microprocessor number)

 

 

 

 

 

 

that the air baffle is in place

 

 

 

 

 

 

 

 

and correctly installed, and

 

 

 

 

that the server cover is

 

 

 

 

installed and completely

 

 

 

 

closed.

 

 

 

2. Make sure that the heat sink

 

 

 

 

for microprocessor n is

 

 

 

 

installed correctly.

 

 

 

3.

(Trained service technician

 

 

 

 

only) Replace microprocessor

 

 

 

 

n.

 

 

 

(n = microprocessor number)

 

 

 

 

 

Sensor CPU nOverTemp has

Error

A sensor has changed to

1.

Make sure that the fans are

transitioned to non-recoverable from

 

Nonrecoverable state from a

 

 

operating, that there are no

a less severe state.

 

less severe state.

 

 

 

obstructions to the airflow,

(n = microprocessor number)

 

 

 

 

 

 

that the air baffle is in place

 

 

 

 

 

 

 

 

and correctly installed, and

 

 

 

 

that the server cover is

 

 

 

 

installed and completely

 

 

 

 

closed.

 

 

 

2. Make sure that the heat sink

 

 

 

 

for microprocessor n is

 

 

 

 

installed correctly.

 

 

 

3.

(Trained service technician

 

 

 

 

only) Replace microprocessor

 

 

 

 

n.

 

 

 

(n = microprocessor number)

 

 

 

 

 

Sensor CPU nOverTemp has

Error

A sensor has changed to

1.

Make sure that the fans are

transitioned to critical from a

 

Critical state from

 

 

operating, that there are no

non-recoverable state.

 

Nonrecoverable state.

 

 

 

obstructions to the airflow,

(n = microprocessor number)

 

 

 

 

 

 

that the air baffle is in place

 

 

 

 

 

 

 

 

and correctly installed, and

 

 

 

 

that the server cover is

 

 

 

 

installed and completely

 

 

 

 

closed.

 

 

 

2. Make sure that the heat sink

 

 

 

 

for microprocessor n is

 

 

 

 

installed correctly.

 

 

 

3.

(Trained service technician

 

 

 

 

only) Replace microprocessor

 

 

 

 

n.

 

 

 

(n = microprocessor number)

 

 

 

 

 

Chapter 4. Diagnostics 33

Page 41
Image 41
Lenovo RS210 manual Sensor CPU nOverTemp has