Table 5. DSA Preboot messages (continued)

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained service technician.

vGo to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new device drivers or to submit a request for information.

Message

 

 

 

 

 

number

Component

Test

State

Description

Action

 

 

 

 

 

 

405-903-xxx

BroadCom

Test Internal

Failed

 

1. Make sure that the component firmware is at the

 

Ethernet

Memory

 

 

 

 

 

latest level. The installed firmware level is shown

 

Device

 

 

 

 

 

 

 

in the DSA event log in the Firmware/VPD

 

 

 

 

 

 

 

 

 

 

section for this component. For more information,

 

 

 

 

 

see “Updating the firmware” on page 212.

 

 

 

 

 

2. Run the test again.

 

 

 

 

 

3. Check the interrupt assignments in the PCI

 

 

 

 

 

Hardware section of the DSA event log. If the

 

 

 

 

 

Ethernet device is sharing interrupts, if possible,

 

 

 

 

 

use the Setup utility see “Using the Setup Utility”

 

 

 

 

 

on page 200) to assign a unique interrupt to the

 

 

 

 

 

device.

 

 

 

 

 

4. Replace the component that is causing the error. If

 

 

 

 

 

the error is caused by an adapter, replace the

 

 

 

 

 

adapter. Check the PCI Information and Network

 

 

 

 

 

Settings information in the DSA event log to

 

 

 

 

 

determine the physical location of the failing

 

 

 

 

 

component.

 

 

 

 

 

5. If the failure remains, go to the Lenovo Web site

 

 

 

 

 

for more troubleshooting information at

 

 

 

 

 

http://www.lenovo.com/support..

 

 

 

 

 

 

405-904-xxx

BroadCom

Test Interrupt

Failed

 

1. Make sure that the component firmware is at the

 

Ethernet

 

 

 

 

 

 

 

latest level. The installed firmware level is shown

 

Device

 

 

 

 

 

 

 

in the DSA event log in the Firmware/VPD

 

 

 

 

 

 

 

 

 

 

section for this component. For more information,

 

 

 

 

 

see “Updating the firmware” on page 212.

 

 

 

 

 

2. Run the test again.

 

 

 

 

 

3. Check the interrupt assignments in the PCI

 

 

 

 

 

Hardware section of the DSA event log. If the

 

 

 

 

 

Ethernet device is sharing interrupts, if possible,

 

 

 

 

 

use the Setup utility see “Using the Setup Utility”

 

 

 

 

 

on page 200) to assign a unique interrupt to the

 

 

 

 

 

device.

 

 

 

 

 

4. Replace the component that is causing the error. If

 

 

 

 

 

the error is caused by an adapter, replace the

 

 

 

 

 

adapter. Check the PCI Information and Network

 

 

 

 

 

Settings information in the DSA event log to

 

 

 

 

 

determine the physical location of the failing

 

 

 

 

 

component.

 

 

 

 

 

5. If the failure remains, go to the Lenovo Web site

 

 

 

 

 

for more troubleshooting information at

 

 

 

 

 

http://www.lenovo.com/support..

 

 

 

 

 

 