Lenovo RS210 manual

Models: RS210

1 244
Download 244 pages 35.96 Kb
Page 74
Image 74
3.Remove the server cover and look inside the server for lit LEDs. Certain components inside the server have LEDs that will be lit to indicate the location of a problem. For example, a DIMM error will light the LED next to the failing DIMM on the system board.

3.Remove the server cover and look inside the server for lit LEDs. Certain components inside the server have LEDs that will be lit to indicate the location of a problem. For example, a DIMM error will light the LED next to the failing DIMM on the system board.

Look at the system service label inside the side cover of the server, which gives an overview of internal components. This information can often provide enough information to correct the error.

The following table describes the LEDs on the system board and PCI extender cards and suggested actions to correct the detected problems.

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Component LED

Description

Action

 

 

 

 

DIMM error LEDs

A memory DIMM has failed or is

1.

Remove the DIMM that has the lit error LED.

 

incorrectly installed.

 

2.

Reseat the DIMM.

 

 

 

 

3. Replace the following components one at a time,

 

 

 

in the order shown, restarting the server each

 

 

 

time:

 

 

 

a. DIMM

 

 

 

b. (Trained service technician only) System board

 

 

 

 

CPU error LEDs

Microprocessor has failed, is

1.

Check the system-event log to determine the

 

missing, or has been incorrectly

 

 

reason for the lit LED.

 

installed.

 

 

2.

(Trained service technician) Reseat the failing

 

Note: (Trained service technician

 

 

microprocessor

 

only) Make sure that the

 

 

3.

Replace the following components one at a time,

 

microprocessor is installed correctly;

 

see “Installing the microprocessor”

 

in the order shown, restarting the server each

 

on page 141.

 

time:

 

 

 

a. (Trained service technician only) Failing

 

 

 

microprocessor

 

 

 

b. (Trained service technician only) System board

 

 

 

System-board error

System-board CPU VRD and/or

(Trained service technician only) Replace the system

LED

power voltage regulators have

board.

 

failed.

 

 

 

 

 

 

Battery failure LED

Battery low.

1.

Replace the CMOS lithium battery, if necessary.

 

 

 

 

2. (Trained service technician only) Replace the

 

 

 

system board.

 

 

 

IMM heartbeat LED

Indicates the status of the boot

If the LED does not begin flashing within 30 seconds

 

process of the IMM.

of when the server is connected to power, complete

 

When the server is connected to

the following steps:

 

1.

(Trained service technician only) Rerecover the

 

power this LED flashes quickly to

 

 

firmware (see “Recovering the server firmware”

 

indicate that the IMM code is

 

 

 

on page 100).

 

loading. When the loading is

 

 

2. (Trained service technician only) Replace the

 

complete, the LED stops flashing

 

 

system board.

 

briefly and then flashes slowly to

 

 

 

 

 

indicate that the IMM if fully

 

 

 

operational and you can press the

 

 

 

power-control button to start the

 

 

 

server.

 

 

 

 

 

 

66ThinkServer ThinkServer RS210, Types 6531, 6532, 6533, and 6534: Hardware Maintenance Manual

Page 74
Image 74
Lenovo RS210 manual