vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

A PCI SERR has occurred on system

Error

A PCI SERR has occurred.

1.

Check the extender-card

%1.

 

(Sensor = One of PCI Err)

 

 

LEDs.

(%1 = CIM_ComputerSystem.

 

 

 

 

 

2.

Reseat the affected adapters

ElementName)

 

 

 

 

 

and extender card.

 

 

 

 

 

 

 

3.

Update the server and

 

 

 

 

adapter firmware (UEFI and

 

 

 

 

IMM).

 

 

 

 

Important: Some cluster

 

 

 

 

solutions require specific code

 

 

 

 

levels or coordinated code

 

 

 

 

updates. If the device is part

 

 

 

 

of a cluster solution, verify

 

 

 

 

that the latest level of code is

 

 

 

 

supported for the cluster

 

 

 

 

solution before you update

 

 

 

 

the code.

 

 

 

4.

Remove both adapters.

 

 

 

5.

Replace the PCIe adapter.

 

 

 

6.

Replace the extender card.

 

 

 

7.

(Trained service technician

 

 

 

 

only) Replace the system

 

 

 

 

board.

 

 

 

 

 

Fault in slot System board on system

Error

 

1.

Check the extender-card

%1.

 

 

 

 

 

LEDs.

(%1 = CIM_ComputerSystem.

 

 

 

 

 

2.

Reseat the affected adapters

ElementName)

 

 

 

 

 

and extender card.

 

 

 

 

 

 

 

3.

Update the server and

 

 

 

 

adapter firmware (UEFI and

 

 

 

 

IMM).

 

 

 

 

Important: Some cluster

 

 

 

 

solutions require specific code

 

 

 

 

levels or coordinated code

 

 

 

 

updates. If the device is part

 

 

 

 

of a cluster solution, verify

 

 

 

 

that the latest level of code is

 

 

 

 

supported for the cluster

 

 

 

 

solution before you update

 

 

 

 

the code.

 

 

 

4.

Remove both adapters.

 

 

 

5.

Replace the PCIe adapter.

 

 

 

6.

Replace the extender card.

 

 

 

7.

(Trained service technician

 

 

 

 

only) Replace the system

 

 

 

 

board.

 

 

 

 

 

42ThinkServer ThinkServer RS210, Types 6531, 6532, 6533, and 6534: Hardware Maintenance Manual