vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

vGo to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new device drivers or to submit a request for information.

Error code

Description

Action

 

 

 

 

3058004

Three boot failure

1.

Undo any recent system changes, such as new

 

 

 

 

 

settings or newly installed devices.

 

 

2.

Make sure that the server is attached to a reliable

 

 

 

power source.

 

 

3.

Make sure that the operating system is not

 

 

 

corrupted.

 

 

4.

Run the Setup utility, save the configuration, and

 

 

 

then restart the server.

 

 

5.

See “Problem determination tips” on page 104.

 

 

 

3108007

System configuration restored to default

Information only. This message is usually associated

 

settings

with the CMOS battery clear event.

 

 

 

 

3138002

Boot configuration error

1.

Remove any recent configuration changes made

 

 

 

 

 

to the Setup utility.

 

 

2.

Run the Setup utility, select Load Default

 

 

 

Settings, and save the settings.

 

 

 

 

3808000

IMM communication failure

1.

Remove power from the server for 30 seconds,

 

 

 

 

 

and then reconnect the server to power and

 

 

 

restart it.

 

 

2.

Update the IMM firmware to the latest level (see

 

 

 

“Updating the firmware” on page 212).

 

 

3.

Make sure that the virtual media key is seated

 

 

 

and not damaged.

 

 

4.

(Trained service technician only) Replace the

 

 

 

system board.

 

 

 

 

3808002

Error updating system configuration to IMM

1.

Remove power from the server, and then

 

 

 

reconnect the server to power and restart it.

 

 

2.

Run the Setup utility and select Save Settings.

 

 

3.

Update the IMM firmware to the latest level (see

 

 

 

“Updating the firmware” on page 212).

 

 

 

 

3808003

Error retrieving system configuration from

1.

Remove power from the server, and then

 

IMM

 

 

reconnect the server to power and restart it.

 

 

 

 

 

2.

Run the Setup utility and select Save Settings.

 

 

3.

Update the IMM firmware to the latest level (see

 

 

 

“Updating the firmware” on page 212).

 

 

 

 

Chapter 4. Diagnostics 27