vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Sensor CPU nOverTemp has

Error

A sensor has changed to

1.

Make sure that the fans are

transitioned to non-recoverable.

 

Nonrecoverable state.

 

 

operating, that there are no

(n = microprocessor number)

 

 

 

 

 

 

obstructions to the airflow,

 

 

 

 

 

 

 

 

that the air baffle is in place

 

 

 

 

and correctly installed, and

 

 

 

 

that the server cover is

 

 

 

 

installed and completely

 

 

 

 

closed.

 

 

 

2. Make sure that the heat sink

 

 

 

 

for microprocessor n is

 

 

 

 

installed correctly.

 

 

 

3.

(Trained service technician

 

 

 

 

only) Replace microprocessor

 

 

 

 

n.

 

 

 

(n = microprocessor number)

 

 

 

 

 

A bus timeout has occurred on

Error

A bus timeout has occurred.

1.

Remove the adapter from the

system %1.

 

 

 

 

 

PCI slot that is indicated by a

(%1 = CIM_ComputerSystem.

 

 

 

 

 

 

lit LED.

ElementName)

 

 

 

 

 

2.

Replace the extender card.

 

 

 

 

 

 

3. Remove all PCI adapters.

 

 

 

4.

(Trained service technicians

 

 

 

 

only) Replace the system

 

 

 

 

board.

 

 

 

 

 

The System %1 encountered a POST

Error

A POST error has occurred.

1.

Recover the server firmware

Error.

 

(Sensor = ABR Status)

 

 

from the backup page (see

(%1 = CIM_ComputerSystem.

 

 

 

 

 

 

“Recovering the server

ElementName)

 

 

 

 

 

 

firmware” on page 100).

 

 

 

 

 

 

 

2. Update the server firmware to

 

 

 

 

the latest level.

 

 

 

 

Important: Some cluster

 

 

 

 

solutions require specific code

 

 

 

 

levels or coordinated code

 

 

 

 

updates. If the device is part

 

 

 

 

of a cluster solution, verify

 

 

 

 

that the latest level of code is

 

 

 

 

supported for the cluster

 

 

 

 

solution before you update

 

 

 

 

the code.

 

 

 

 

 

34ThinkServer ThinkServer RS210, Types 6531, 6532, 6533, and 6534: Hardware Maintenance Manual