Lenovo RS210 manual Replacing the microprocessor and heat sink

Models: RS210

1 244
Download 244 pages 35.96 Kb
Page 147
Image 147
Replacing the microprocessor and heat sink

To install a drive cage, complete the following steps:

1.Make sure that the backplane or back plate is removed from the drive cage. (See “Removing the backplane or back plate (3.5-inch drives)” on page 154 or “Removing the SAS backplane (2.5-inch drives)” on page 156 for instructions, as applicable.)

2.Line up the drive cage with the drive bays on the front of the server.

3.Push the drive cage into the server until it stops.

4.Align the holes in the top of the drive cage with the holes in the top of the chassis; then, insert the screws that secure the drive cage to the chassis.

5.Install the backplane or back plate. (See “Installing the backplane or back plate (3.5-inch drives)” on page 154 or “Installing the SAS backplane (2.5-inch drives)” on page 157 for instructions, as applicable.)

6.Install the hard disk drives.

7.Go to “Completing the FRU replacement” on page 173.

Replacing the microprocessor and heat sink

The following notes describe the type of microprocessor that the server supports and other information that you must consider when you install a microprocessor:

vThe server supports one Intel land grid array (LGA) 1156 dual-core or quad-core microprocessor. The type, speed, and L3 cache of the microprocessor depends on the server model.

vRead the documentation that comes with the microprocessor to determine whether you have to update the server firmware. To download the most current level of server firmware, go to

Chapter 6. Replacing FRUs 139

Page 147
Image 147
Lenovo RS210 manual Replacing the microprocessor and heat sink