IMC Networks E1, IE-IMCV-T1 operation manual Loopback Modes

Page 13

Loopback Modes

This feature allows three distinct Loopbacks to be activated either through DIP Switches or iView2 Management.

Fiber

An analog Loopback at the copper port back to the fiber port. It

Loopback

copies the received optical signal back to the optical line at the

 

copper port and continues to drive the copper port, but can be

 

corrupted by noise on the copper port.

Internal

A local Loopback at the fiber port. It copies the received optical

Fiber

signal back to the optical line at a digital point internal to the unit.

Loopback

It continues to drive the copper port, and normal copper line

 

monitoring is maintained on the copper port, but the returning

 

data pattern is not affected.

Copper

A remote Loopback to copper port at the fiber driver. It copies

Loopback

the received copper signal back to the copper port and continues

 

to drive the fiber port.

By default all Loopbacks are set to OFF for normal data operation.

The following illustrations show the path that a signal takes in each of the Loopback test modes.

This feature can be controlled by SNMP–Management software (iView2) when the HOST IE-iMcV-T1/E1/J1-LineTerm, TP/SFP module is installed in a managed chassis.

10

Image 13
Contents IE-iMcV-T1/E1/J1-LineTerm SFP FCC Radio Frequency Interference Statement WarrantyTable of Contents IE-iMcV-T1/E1/J1-LineTerm in this manual About the IE-iMcV-T1/E1/J1-LineTerm, TP/SFPPage Managed Modules Configuration Control Unmanaged Modules IView² Management SoftwareDIP Switches Switch Settings for Switch S2 DIP Switch Settings S2, S3Switch Settings for Switch S3 SFP FeaturesLoopback Loopback ModesTransmit LIU Waveshape and Gain Line Build-Out Fault LoopbackTransmit Data Source Remote Management T1, E1 and J1 SelectionCopper Port LEDs LED OperationLoopback Testing Installation Troubleshooting General Troubleshooting Pseudorandom Bit Sequence Prbs TestingPin Signal IMC Networks Technical Support SpecificationsFiber Optic Cleaning Guidelines Electrostatic Discharge Precautions Certifications Document Number 50-80104-00 A1