IMC Networks IE-IMCV-T1, E1 operation manual IView² Management Software, Unmanaged Modules

Page 8

NOTE

If the end user has a mixture of standard iMcV-Modules as well as Configuration Control iMcV-Modules, it is important to understand how SNMP and DIP Switches will impact the cards depending on their capability. Standard iMcV-Modules cannot be upgraded to Configuration Control capability, so it is strongly recommended to set the DIP Switches on the modules and then configure them via software to match the same settings.

iView² Management Software

iView² is the IMC Networks management software designed specifically for the IMC Networks “iMcV” family of modules. It features a GUI and gives network managers the ability to monitor and control the manageable IMC Networks products.

iView² is available in several versions, including WebServer version 3.0, and can also function as a snap-in module for HP OpenView Network Node Manager and other third party SNMP Management software. For assistance in selecting the right version of iView² for your operating system, please visit: http://www.imcnetworks.com/products/iview2.cfm

iView2 supports the following platforms:

Windows 2000

Windows XP

Windows Vista

Windows 7

Please see the SNMP Management Module installation guide for software configuration options.

Unmanaged Modules

Before installing the module in an unmanaged chassis, manually configure all of the desired DIP Switch selectable features. Refer to Tables on page 7 and 8.

Modules must be configured as a HOST-REMOTE pair via DIP Switches. Modules are shipped in the default setting as a HOST.

HOST: S3-2 OFF

REMOTE: S3-2 ON

5

Image 8
Contents IE-iMcV-T1/E1/J1-LineTerm SFP Warranty FCC Radio Frequency Interference StatementTable of Contents About the IE-iMcV-T1/E1/J1-LineTerm, TP/SFP IE-iMcV-T1/E1/J1-LineTerm in this manualPage Managed Modules Configuration Control IView² Management Software Unmanaged ModulesDIP Switches DIP Switch Settings S2, S3 Switch Settings for Switch S2Switch Settings for Switch S3 Features SFPLoopback Modes LoopbackTransmit Data Source Fault LoopbackTransmit LIU Waveshape and Gain Line Build-Out T1, E1 and J1 Selection Remote ManagementLED Operation Copper Port LEDsLoopback Testing Pseudorandom Bit Sequence Prbs Testing Installation Troubleshooting General TroubleshootingPin Signal Specifications IMC Networks Technical SupportFiber Optic Cleaning Guidelines Electrostatic Discharge Precautions Certifications Document Number 50-80104-00 A1