Item

 

Requirements

Result

 

Temperature

0°C to 45°C (32°F to 113°F).

 

 

 

 

 

 

Relative humidity

5% to 90% (noncondensing).

 

 

 

 

 

 

Cleanness

Dust concentration ≤ 3 × 104 particles/m3. (No

 

 

visible dust on desk within three days.)

 

 

 

 

 

 

 

 

 

 

The equipment and floor are correctly grounded.

 

 

 

The equipment room is dust-proof.

 

 

 

The humidity and temperature are at a compliant

 

 

 

level.

 

 

 

Wear an ESD wrist strap and uniform when

 

 

ESD prevention

touching a circuit board.

 

 

Place the removed interface module on an

 

 

 

 

 

 

antistatic workbench, with the face upward, or put

 

 

 

it into an antistatic bag.

 

 

 

Touch only the edges, instead of electronic

 

 

 

components when observing or moving a removed

 

 

 

interface module.

 

 

 

 

 

 

 

Take effective measures to reduce interference

 

 

 

from the power grid system.

 

 

 

Separate the grounding equipment of the router

 

 

 

from the grounding or lightning protection

 

 

EMI prevention

grounding equipment of other devices as far as

 

 

possible.

 

 

 

 

 

 

Keep the router far away from radio stations, radar

 

 

 

and high-frequency devices working in high

 

 

 

current.

 

 

 

Use electromagnetic shielding when necessary.

 

 

 

 

 

 

 

The grounding cable of the chassis is correctly

 

 

 

grounded.

 

 

 

The grounding terminal of the AC power

 

 

Lightning

receptacle is correctly grounded.

 

 

A port lightning arrester is installed. (Optional.)

 

 

protection

 

 

 

A power lightning arrester is installed. (Optional.)

 

 

 

A signal lightning arrester is installed at the input

 

 

 

end of an external signal cable. (Optional.)

 

 

 

 

 

 

 

Equip an uninterrupted power supply (UPS).

 

 

Electricity safety

The emergency power switch in the equipment

 

 

 

room is located.

 

 

 

 

 

 

Workbench

The workbench is stable enough.

 

 

The workbench is correctly grounded.

 

 

 

 

 

 

 

 

 

 

The rack has a good ventilation system.

 

 

 

The rack is sturdy enough to support the weight of

 

 

Rack-mounting

the router and installation accessories.

 

 

requirements

The size of the rack is appropriate for the router.

 

 

 

The front and rear of the rack are at least 0.8 m

 

 

 

(2.62 ft) away from walls or other devices.

 

 

 

 

Safety

The router is far away from any moist area and heat source.

 

precautions

The emergency power switch in the equipment room is located.

 

 

 

 

 

6

Page 10
Image 10
HP MSR1000 Router manual Components when observing or moving a removed