Kathrein DCM 32, DCM 42 I manual Specifications, Downstream

Page 27

Specifications

 

The DCM 32 corresponds to the specification

 

MCNS DOCSIS 1.0,1.1, 2.0. The DCM 42 corre-

 

sponds to the specification EURODOCSIS

 

1.0,1.1, 2.0.

Downstream

 

Demodulation

64 QAM / 256 QAM

Input level

-15 dBmV to +15 dBmV

Input impedance

75 Ω

Return loss

>6 dB from 88 MHz to 860 MHz

DCM 32

 

Physical speed

30 Mb/s (64 QAM) / 43 Mb/s (256 QAM)

Error correction

Reed Solomon + Trellis (ITU-T J.83 Annex B)

Frequency range

88 MHz to 860 MHz (edge frequencies) in

 

62.5 kHz steps

Band width

6 MHz

DCM 42 / 42 I

 

Physical speed

42 Mb/s (64 QAM) / 56 Mb/s (256 QAM)

Error correction

Reed Solomon (ITU-T J.83 Annex A)

Frequency range

108 MHz to 860 MHz (edge frequencies) in

 

250 kHz steps

Band width

8 MHz

Upstream

 

Access method

TDMA, S-CDMA (DOCSIS 2.0)

Modulation

QPSK, 8-,16-, 32- and 64QAM, 128QAM with S-CDMA only

Modulationsrate

TDMA: 160, 320, 640, 1280, 2560 und 5120 kHz

 

S-CDMA: 1280, 2560 and 5120 kHz

Bandwidth

TDMA: 200, 400, 800, 1600, 3200 and 6400 kHz

 

S-CDMA: 1600, 3200 and 6400 kHz

Output level

TDMA:

 

+8 dBmV to 53 dBmV (32QAM, 64QAM)

 

+8 dBmV to 55 dBmV (8QAM, 16QAM)

 

+8 dBmV to 58 dBmV (QPSK)

 

S-CDMA:

 

+8 dBmV to 53 dBmV (all Modulations)

Max. Bitrate

30 Mbit/s (with A-TDMA- or S-CDMA)

Error correction

Reed Solomon

27

Image 27
Contents Bestell-Nr./ Order No./ Référence 26210042 26210043 Bedienungsanleitung Operating Manual Mode demploiPage Inhalt / Contents / Sommaire Children at play Definiert Vorwort Anschlüsse und Anzeigen Wichtige Hinweise zum Betrieb SicherheitshinweiseAnschlüsse ReparaturFeuchtigkeit Aufstellungsort und MontageAufstellungsort LüftungNetzspannung ErdungHF-Anschluss Installation VoraussetzungenAnschlüsse Installation Ausfall der Datenübertragung Betriebsanzeigen und FehlerdiagnoseTechnische Daten DownstreamUpstream Umgebungsbedingungen Snmp ManagementSchnittstellen Mechanische DatenAnschlussschema Preface Connections and displays Important notes regarding operation Safety instructionsConnections RepairsExposure to sunlight, heat Putting into operationVentilation HumidityMains voltage GroundingRF-connection Connections PreconditionsInstallation Failure of data transmission Status indicators and error diagnosisSpecifications Scope of delivery InterfacesPhysical data Ambient conditionsConnection scheme Avant propos Branchements et affichages Remarques importantes concernant lutilisation Consignes de sécuritéRaccordements RéparationHumidité Lieu dinstallation et montageLieu dinstallation AérationBranchement RF Mise à la terreRaccordements Conditions préalablesInstallation Défaillance de la transmission de données Affichages de service Diagnostique derreurAffichages de service Diagnostique derreur Caractéristiques techniques Fourniture standard Gestion SnmpCaractéristiques mécaniques Conditions environnantesSchéma des connexions Notizen Notizen