Version 1.0 06/2001 |
'/XSTOP' or '/YSTOP' signal become to '0'.
Register | Add. | R/W | Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 |
WRFF | 0x01 | W |
|
| Command port | |||||
Register | Add. | R/W | Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 |
RSTFF | 0x02 | W |
|
| Reset FIFO | |||||
This register is used to reset FIFO for clear all of commands pending in the FIFO buffer.
2.3 LED Indicator
power
/ORG1 /LS11 /LS14 /ORG2 /LS21 /LS24 /EMG
Fig.(4) I-8091 LED indicator
Where
/ORG1: X-axis’s original limit switch for machine home position.
/LS11, /LS14 : X-axis’s negative and positive limit switches.
/ORG2: Y-axis’s original limit switch for machine home position.
/LS21, /LS24 : Y-axis’s negative and positive limit switches.
/EMG : system’s emergency signal input.
http://www.icpdas.com | ICPDAS |