GarrettCom 6K16V Introduction 2.1 Inspecting the Package and Product, www . GarrettCom . com

Page 13
2.0Introduction

Magnum 6K16V Managed Fiber Switch

Installation and User Guide (06/04)

2.0Introduction

2.1Inspecting the Package and Product

Examine the shipping container for obvious damage prior to installing this

product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.

This package should contain:

1Magnum 6K16V Managed Fiber Switch, base unit (configured with user-selected port module options installed)

1 AC Power Cord (U.S. and other 115 VAC only)

1Set of two metal vertical mounting brackets, with screws to the case

1Installation and User Guide (this manual)

1Product Registration Card

Remove the items from the shipping container. Be sure to keep the shipping container should you need to re-ship the unit at a later date. To validate the product warranty, please complete and return the enclosed Product Registration Card to GarrettCom, Inc. as soon as possible.

In the event there are items missing or damaged, contact the party from whom you purchased the product. If the unit needs to be returned, please use the original shipping container if possible. Refer to Section 6, Troubleshooting, for specific return procedures.

www . GarrettCom . com

6

Image 13
Contents Managed Fiber Switch www . GarrettCom . comInstallation and User Guide HardwareInstallation and User Guide Magnum 6K16V Managed Fiber Switch HardwareTrademarks Federal Communications Commission Contacting GarrettCom, IncRadio Frequency Interference Statement Reorient or relocate the receiving antennaInstallation SPECIFICATIONSIntroduction OPERATIONTROUBLESHOOTING 5.0 Introduction - Magnum 6K16V Managed Fiber Switch PMAPPENDIX A WARRANTY INFORMATION APPENDIX B Internal DC Power Supply OptionsQUAD-SERIES FIBER SWITCHES, 100 & 10MBPS, FIBER AND 6K-SERIES MANAGED FIBER SWITCHES, GIGABIT, 100 AND“OUTDOOR” ETHERNET SWITCH, FOR TEMPERATURE PERSONAL SWITCHES, 10/100MBBRIDGE PORT MODULES BPMS, 4 TYPES, FOR SEGMENT MEDIA CONVERTERS, 10MB AND 100MB SERIESTRANSCEIVERS, 10MB SERIES MINI-TRANSCEIVERS AND COAX MODELSFiber Multi-mode connector types supported 1.0 SPECIFICATIONS 1.1 Technical SpecificationsPerformance Network Standards and Compliance, hardwareAlarm Relay Contacts Fiber Single-mode connector typesManagement Console connector Power Supply InternalAgency Approvals Per-port jumpers and switchesNEBS Test Classification NEBS Compliant Email sales@GarrettCom.com for detailsConfiguration Options Magnum Managed Fiber Switch 16 ports maxMODEL DESCRIPTION 1.2 Ordering Informationfiber ports connector 2.0 Introduction 2.1 Inspecting the Package and Product 2.2 Product Description - Magnum 6K16V Managed Fiber Switch 2.2.1 Eight-port SFF fiber modules 6K8-MTRJ, 6K8-MLC, 100Mb fiber 100Mb, mode, and connectorFig.2.2.2 SFF Fiber Port Modules 6K8-MTRJ to the left and 6K8-MLC or -SLC below2.2.2 Eight-Port Copper Module, 6K8-RJ45 The Magnum Combo 4@ RJ-45 + 2@ 100Mb SCsix-port modules are also available with 4@ MTRJ 100Mb mm SFF2.2.6 Gigabit 1000Mbps port modules 2.2.4 Four-Port 10 Mb and 100Mb mm Fiber ST Modules1@ 1000Mb Fiber SC + 2@ 100Mb SC 1@ 1000Mb Fiber SC + 4@10/ 100Mb2.2.7 Frame Buffering and Flow Control 2.2.6 Packet Prioritization, 802.1p QOSftp//ftp.garrettcom.com 2.2.8 Managed Network Software MNS-6K for Magnum 6K16V„ Managed switching for high performance Ethernet LANs 2.3 Features and Benefits„ Switching services includes 802.1p QoS packet prioritization „ Features Fiber-Built-In2.4 Applications Example 1 Magnum 6K16V Switch for a Industrial applicationInternet Fig. 2.1- The Industrial factory floor application with Magnum 6K16VSNMP Monitor 3.1 Locating Magnum 6K16V Switches 3.0 Installation3.2 Connecting Ethernet Media 3.2.2 Connecting Fiber Optic SC-type, Snap-In 3.2.1 Connecting Fiber Optic ST-type, “twist-lock”3.2.3 Connecting Single-Mode Fiber Optic IEEE StandardMedia 3.2.5 Connecting Twisted Pair CAT5E or better, Unshielded or Shielded3.3 DIN-Rail Mounting 3.2.6 Connecting Gigabit Media Using GBICs3.3.1 Mounting Dimensions for 6K16V with metal brackets 3.4 Powering the Magnum 6K16V Managed Fiber Switch Relay Contacts 3.5 Alarm Contacts for monitoring internal power, and Software Traps3.6.1 Preparation for Installing and Removing 6KPMs 3.6 6K16V Port Module 6KPM InstallationBe sure the power cord is unplugged and will void the warrantyStep 2. Remove Chassis Cover Caution Be careful not to disturb the power supplyFigure 3.6.1a Removing the Front panel from the unit Figure 3.6.1b Magnum 6K16V, Top view without chassis coverStep 3. Remove front panel face plate retaining screws 3.6.2 Installing 6KPM Cards in the Magnum 6K16VFigure 3.6.1c Top View - 6KPM retaining screws hold Face Plate Fig 3.6.2a Granddaughter Board shown separatelyversion for 4 copper 10/100 ports Fig. 3.6.2c Daughter Board, top view ofFigure 3.6.2f Securely latching up 6KPM Cards into a Magnum 6K16V Fig. 3.6.2g Top View 6KPM Module installed inside a 6K16V3.6.3 Removing 6KPM Cards Caution Be sure the power cord is unpluggedfirmly. Figure 3.6.3a Top View - 6 retaining s crews shown by arrows Step 3. Remove 6KPM CardDB-9 Console port connector 3.7 Connecting a Management Console Terminal to Magnum 6K16V3.7.1 RS-232 DB-9 Console Com port Serial port pin assignments Enlarged view of Magnum 6K16V Console Port area4.0 OPERATION 4.1 Switching FunctionalityFiltering and Forwarding Address LearningPower LED, ON when external power is applied to the unit 4.3 Up-link Manual Switches set as = , for RJ-45 port onlyFull / Half duplex LED, ON when the port is running full Speed LED, ON when the speed is 100Mbps , OFF when theAuto-negotiation per-port for 802.3u-compliant switches occurs when 4.5 Flow-control, IEEE 802.3x standard 4.6 Power Budget Calculations for Magnum 6K16V PM’s with Fiber MediaLXSC40 and the “Cable Loss” for 9/125 Single-mode is 0.2 dB/km LXSC70 Installation and User Guide 06/04 Magnum 6K16V Managed Fiber Switch6KP4V Km, fdx5.1 Inspecting the Package and Product 5.0 Introduction - Magnum 6K16V Managed Fiber Switch Port Modules5.2 6KPM Module Description 5.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module and configured as 10Mb ports are ST connectorsHalf-duplex by default connectors and configuredmodule of the 6K16V Switch mode SC-type connectors. ItThe Magnum 6KP6 RJMSC is also a Combo 6 Portas 25+ Km see Power Budget, Section 5.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factor “small-form-factor”The functionality of this 100BASE-FX multi-mode 4 port module is 6KP8-MTRJ5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX MTRJ connectors give an advantageMTRJ Small-Form-Factor The Magnum 6KP8-45MT5.2.9 6KP8-RJ45 Twisted Pair, 10/100Mb 8-Port connecting to a hub or another switch 6KP8V 5.2.11 GBIC-SXSC Gigabit fiber1000Mb, multi-mode SC ConnectorSingle-Mode Fiber port LC 5.2.12 6KM-BLNK 5.2.11a GBIC-LXSC Gigabit fiber 1000Mb, multi-mode SC Connector6.1 Before Calling for Assistance 6.0 TROUBLESHOOTING6.3 Return Material Authorization RMA Procedure 6.2 When Calling for AssistanceGarrettCom, Inc 213 Hammond Ave Fremont, CA Attn. Customer Service No Problem Found6.4 Shipping and Packaging Information B2.0 -48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION B1.0 SPECIFICATIONS FOR MAGNUM 6K16V SWITCHES, DC POWERB4.0 6K16V’S -48V, 24, 125 OR 5VDC INSTALLATION B3.0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHESB7.0 TROUBLESHOOTING B4.1 UL Requirements for DC-powered unitshooked up at the last B5.0 OPERATIONPower Supply Internal, 125VDC Dual-Source, model # Dual-Src-125V Power Supply Internal, 24VDC Dual-Source, model # Dual-Src-24VC3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION C5.0 INSTALLATION C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGNC6.0 ORDERING INFORMATION C5.1 UL RequirementsExample Magnum 6K16VR-48VDC C7.0 OPERATION