GarrettCom 6K16V Contacting GarrettCom, Inc, Federal Communications Commission, Canadian Emission

Page 3
Contacting GarrettCom, Inc

Magnum 6K16V Managed Fiber Switch Installation and User Guide

(06/04)

Contacting GarrettCom, Inc

Please use the mailing address, phone and fax numbers and email address listed below:

GarrettCom, Inc.

213 Hammond Ave.

Fremont, CA 94539

Phone (510) 438-9071
Fax (510) 438-9072

Website: http://www.GarrettCom.com

email support@garrettcom.com

Federal Communications Commission

Radio Frequency Interference Statement

Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference in a residential installation. This equipment generates, uses, and can radiate frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interfernce to radio communications. However, there is no guarantee that interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures.

-Reorient or relocate the receiving antenna.

-Increase the separation between the equipment and receiver.

-Connect the equipment into n outlet on a ccircuit different from that to which the receiver is connected.

-Consult the dealer or an experienced radio TV technician for help.

Canadian Emission

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Cet appareil respecte toutes les exigences du Réglement sur le matériel du Canada. Cet appareil est Classe B.

www . GarrettCom . com

ii

Image 3
Contents Hardware www . GarrettCom . comManaged Fiber Switch Installation and User GuideMagnum 6K16V Managed Fiber Switch Hardware Installation and User GuideTrademarks Reorient or relocate the receiving antenna Contacting GarrettCom, IncFederal Communications Commission Radio Frequency Interference StatementOPERATION SPECIFICATIONSInstallation IntroductionAPPENDIX B Internal DC Power Supply Options 5.0 Introduction - Magnum 6K16V Managed Fiber Switch PMTROUBLESHOOTING APPENDIX A WARRANTY INFORMATIONPERSONAL SWITCHES, 10/100MB 6K-SERIES MANAGED FIBER SWITCHES, GIGABIT, 100 ANDQUAD-SERIES FIBER SWITCHES, 100 & 10MBPS, FIBER AND “OUTDOOR” ETHERNET SWITCH, FOR TEMPERATUREMODELS MEDIA CONVERTERS, 10MB AND 100MB SERIESBRIDGE PORT MODULES BPMS, 4 TYPES, FOR SEGMENT TRANSCEIVERS, 10MB SERIES MINI-TRANSCEIVERS AND COAXNetwork Standards and Compliance, hardware 1.0 SPECIFICATIONS 1.1 Technical SpecificationsFiber Multi-mode connector types supported PerformancePower Supply Internal Fiber Single-mode connector typesAlarm Relay Contacts Management Console connectorEmail sales@GarrettCom.com for details Per-port jumpers and switchesAgency Approvals NEBS Test Classification NEBS Compliant1.2 Ordering Information Magnum Managed Fiber Switch 16 ports maxConfiguration Options MODEL DESCRIPTIONfiber ports connector 2.0 Introduction 2.1 Inspecting the Package and Product 2.2 Product Description - Magnum 6K16V Managed Fiber Switch 6K8-MLC or -SLC below 100Mb, mode, and connector2.2.1 Eight-port SFF fiber modules 6K8-MTRJ, 6K8-MLC, 100Mb fiber Fig.2.2.2 SFF Fiber Port Modules 6K8-MTRJ to the left and2.2.2 Eight-Port Copper Module, 6K8-RJ45 with 4@ MTRJ 100Mb mm SFF 4@ RJ-45 + 2@ 100Mb SCThe Magnum Combo six-port modules are also available1@ 1000Mb Fiber SC + 4@10/ 100Mb 2.2.4 Four-Port 10 Mb and 100Mb mm Fiber ST Modules2.2.6 Gigabit 1000Mbps port modules 1@ 1000Mb Fiber SC + 2@ 100Mb SC2.2.7 Frame Buffering and Flow Control 2.2.6 Packet Prioritization, 802.1p QOSftp//ftp.garrettcom.com 2.2.8 Managed Network Software MNS-6K for Magnum 6K16V„ Features Fiber-Built-In 2.3 Features and Benefits„ Managed switching for high performance Ethernet LANs „ Switching services includes 802.1p QoS packet prioritization2.4 Applications Example 1 Magnum 6K16V Switch for a Industrial applicationInternet Fig. 2.1- The Industrial factory floor application with Magnum 6K16VSNMP Monitor 3.0 Installation 3.1 Locating Magnum 6K16V Switches3.2 Connecting Ethernet Media IEEE Standard 3.2.1 Connecting Fiber Optic ST-type, “twist-lock”3.2.2 Connecting Fiber Optic SC-type, Snap-In 3.2.3 Connecting Single-Mode Fiber OpticMedia 3.2.5 Connecting Twisted Pair CAT5E or better, Unshielded or Shielded3.3 DIN-Rail Mounting 3.2.6 Connecting Gigabit Media Using GBICs3.3.1 Mounting Dimensions for 6K16V with metal brackets 3.4 Powering the Magnum 6K16V Managed Fiber Switch Relay Contacts 3.5 Alarm Contacts for monitoring internal power, and Software Trapsand will void the warranty 3.6 6K16V Port Module 6KPM Installation3.6.1 Preparation for Installing and Removing 6KPMs Be sure the power cord is unpluggedFigure 3.6.1b Magnum 6K16V, Top view without chassis cover Caution Be careful not to disturb the power supplyStep 2. Remove Chassis Cover Figure 3.6.1a Removing the Front panel from the unitFig 3.6.2a Granddaughter Board shown separately 3.6.2 Installing 6KPM Cards in the Magnum 6K16VStep 3. Remove front panel face plate retaining screws Figure 3.6.1c Top View - 6KPM retaining screws hold Face Plateversion for 4 copper 10/100 ports Fig. 3.6.2c Daughter Board, top view ofFigure 3.6.2f Securely latching up 6KPM Cards into a Magnum 6K16V Fig. 3.6.2g Top View 6KPM Module installed inside a 6K16VStep 3. Remove 6KPM Card Caution Be sure the power cord is unplugged3.6.3 Removing 6KPM Cards firmly. Figure 3.6.3a Top View - 6 retaining s crews shown by arrowsEnlarged view of Magnum 6K16V Console Port area 3.7 Connecting a Management Console Terminal to Magnum 6K16VDB-9 Console port connector 3.7.1 RS-232 DB-9 Console Com port Serial port pin assignmentsAddress Learning 4.1 Switching Functionality4.0 OPERATION Filtering and ForwardingSpeed LED, ON when the speed is 100Mbps , OFF when the 4.3 Up-link Manual Switches set as = , for RJ-45 port onlyPower LED, ON when external power is applied to the unit Full / Half duplex LED, ON when the port is running fullAuto-negotiation per-port for 802.3u-compliant switches occurs when 4.6 Power Budget Calculations for Magnum 6K16V PM’s with Fiber Media 4.5 Flow-control, IEEE 802.3x standardLXSC40 and the “Cable Loss” for 9/125 Single-mode is 0.2 dB/km LXSC70 Km, fdx Magnum 6K16V Managed Fiber SwitchInstallation and User Guide 06/04 6KP4V5.0 Introduction - Magnum 6K16V Managed Fiber Switch Port Modules 5.1 Inspecting the Package and Product5.2 6KPM Module Description 5.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module connectors and configured ports are ST connectorsand configured as 10Mb Half-duplex by defaultRJMSC is also a Combo 6 Port mode SC-type connectors. Itmodule of the 6K16V Switch The Magnum 6KP6as 25+ Km see Power Budget, Section 6KP8-MTRJ “small-form-factor”5.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factor The functionality of this 100BASE-FX multi-mode 4 port module isThe Magnum 6KP8-45MT MTRJ connectors give an advantage5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX MTRJ Small-Form-Factor5.2.9 6KP8-RJ45 Twisted Pair, 10/100Mb 8-Port connecting to a hub or another switch 5.2.11 GBIC-SXSC Gigabit fiber1000Mb, multi-mode SC Connector 6KP8VSingle-Mode Fiber port LC 5.2.12 6KM-BLNK 5.2.11a GBIC-LXSC Gigabit fiber 1000Mb, multi-mode SC Connector6.1 Before Calling for Assistance 6.0 TROUBLESHOOTING6.3 Return Material Authorization RMA Procedure 6.2 When Calling for AssistanceNo Problem Found GarrettCom, Inc 213 Hammond Ave Fremont, CA Attn. Customer Service6.4 Shipping and Packaging Information B2.0 -48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION B1.0 SPECIFICATIONS FOR MAGNUM 6K16V SWITCHES, DC POWERB4.0 6K16V’S -48V, 24, 125 OR 5VDC INSTALLATION B3.0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHESB5.0 OPERATION B4.1 UL Requirements for DC-powered unitsB7.0 TROUBLESHOOTING hooked up at the lastPower Supply Internal, 24VDC Dual-Source, model # Dual-Src-24V Power Supply Internal, 125VDC Dual-Source, model # Dual-Src-125VC3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION C5.0 INSTALLATION C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGNC7.0 OPERATION C5.1 UL RequirementsC6.0 ORDERING INFORMATION Example Magnum 6K16VR-48VDC