GarrettCom 6K16V manual B3.0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHES, www . GarrettCom . com

Page 59
B3.0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHES

Magnum 6K16V Managed Fiber Switch

Installation and User Guide (06/04)

applied to the two inputs. It protects the Switch from incorrect DC input connections. An incorrect polarity connection, for example, will neither affect the Switch, its internal power supply, nor will it blow the fuse in the internal power supply.

The manual power “On-Off” Switch (optional) is used for powering the unit on and off when it is placed into or taken out of service.

B3.0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHES

Magnum 6K16-Series Switches are easily installed in a variety of applications where -48VDC, 24, or 125VDC or 5VDC power is used as the primary power source. The DC power configuration capability provides an Ethernet networking solution utilizing a special power supply in switches with a proven track record.

The –48VDC solution is particularly useful in the telecommunication industry, where it is common for facilities to operate on -48VDC power. Such companies include regular and wireless telephone service providers, Internet Service Providers (ISPs) and other communication companies. In addition, many high availability equipment services, such as broadcasters, publishers, newspaper operations, brokerage firms and other facilities often use a battery backup system to maintain operations in the event of a power failure. It is also frequently used for computer system backup, management and operations monitoring equipment.

The 24V and 125VDC options are particularly useful in the Industrial environment, where it is common for facilities to operate on 24VDC or 125VDC power. The 125VDC options are mainly used in power utilities, such as electrical substations, electrical generating plants, etc. The 24VDC applications are mainly in the Industrial environment, such as factory floor, HVAC equipment, military equipment, etc. The 5VDC options are mainly used for military or Industrial factory floor applications.

B4.0 6K16V’S -48V, 24, 125 OR 5VDC INSTALLATION

This section describes the proper connection of the -48VDC leads (or 24VDC/125VDC/5VDC leads) to the DC power terminal block on the Magnum 6K16V Switch. The DC terminal block on the Magnum 6K16V Managed Switch is located on the left front of the unit and is equipped with three (3) screw-down lead posts. The power terminals are identified as positive (+) and negative (-), and they are floating inside the unit so that either may be grounded by the user if desired. The chassis is “earth” or ground (GND).

The connection procedure is straightforward. Simply insert the DC leads to the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely tightened.

NOTE: Always use a voltmeter to measure the voltage of the incoming power supply and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead will connect to the post labeled “+ve” and the rest to the “-ve”. The GND can be

www . GarrettCom . com

52

Image 59
Contents Hardware www . GarrettCom . comManaged Fiber Switch Installation and User GuideTrademarks Magnum 6K16V Managed Fiber Switch HardwareInstallation and User Guide Reorient or relocate the receiving antenna Contacting GarrettCom, IncFederal Communications Commission Radio Frequency Interference StatementOPERATION SPECIFICATIONSInstallation IntroductionAPPENDIX B Internal DC Power Supply Options 5.0 Introduction - Magnum 6K16V Managed Fiber Switch PMTROUBLESHOOTING APPENDIX A WARRANTY INFORMATIONPERSONAL SWITCHES, 10/100MB 6K-SERIES MANAGED FIBER SWITCHES, GIGABIT, 100 ANDQUAD-SERIES FIBER SWITCHES, 100 & 10MBPS, FIBER AND “OUTDOOR” ETHERNET SWITCH, FOR TEMPERATUREMODELS MEDIA CONVERTERS, 10MB AND 100MB SERIESBRIDGE PORT MODULES BPMS, 4 TYPES, FOR SEGMENT TRANSCEIVERS, 10MB SERIES MINI-TRANSCEIVERS AND COAXNetwork Standards and Compliance, hardware 1.0 SPECIFICATIONS 1.1 Technical SpecificationsFiber Multi-mode connector types supported PerformancePower Supply Internal Fiber Single-mode connector typesAlarm Relay Contacts Management Console connectorEmail sales@GarrettCom.com for details Per-port jumpers and switchesAgency Approvals NEBS Test Classification NEBS Compliant1.2 Ordering Information Magnum Managed Fiber Switch 16 ports maxConfiguration Options MODEL DESCRIPTIONfiber ports connector 2.0 Introduction 2.1 Inspecting the Package and Product 2.2 Product Description - Magnum 6K16V Managed Fiber Switch 6K8-MLC or -SLC below 100Mb, mode, and connector2.2.1 Eight-port SFF fiber modules 6K8-MTRJ, 6K8-MLC, 100Mb fiber Fig.2.2.2 SFF Fiber Port Modules 6K8-MTRJ to the left and2.2.2 Eight-Port Copper Module, 6K8-RJ45 with 4@ MTRJ 100Mb mm SFF 4@ RJ-45 + 2@ 100Mb SCThe Magnum Combo six-port modules are also available1@ 1000Mb Fiber SC + 4@10/ 100Mb 2.2.4 Four-Port 10 Mb and 100Mb mm Fiber ST Modules2.2.6 Gigabit 1000Mbps port modules 1@ 1000Mb Fiber SC + 2@ 100Mb SC2.2.7 Frame Buffering and Flow Control 2.2.6 Packet Prioritization, 802.1p QOSftp//ftp.garrettcom.com 2.2.8 Managed Network Software MNS-6K for Magnum 6K16V„ Features Fiber-Built-In 2.3 Features and Benefits„ Managed switching for high performance Ethernet LANs „ Switching services includes 802.1p QoS packet prioritization2.4 Applications Example 1 Magnum 6K16V Switch for a Industrial applicationInternet Fig. 2.1- The Industrial factory floor application with Magnum 6K16VSNMP Monitor 3.2 Connecting Ethernet Media 3.0 Installation3.1 Locating Magnum 6K16V Switches IEEE Standard 3.2.1 Connecting Fiber Optic ST-type, “twist-lock”3.2.2 Connecting Fiber Optic SC-type, Snap-In 3.2.3 Connecting Single-Mode Fiber OpticMedia 3.2.5 Connecting Twisted Pair CAT5E or better, Unshielded or Shielded3.3 DIN-Rail Mounting 3.2.6 Connecting Gigabit Media Using GBICs3.3.1 Mounting Dimensions for 6K16V with metal brackets 3.4 Powering the Magnum 6K16V Managed Fiber Switch Relay Contacts 3.5 Alarm Contacts for monitoring internal power, and Software Trapsand will void the warranty 3.6 6K16V Port Module 6KPM Installation3.6.1 Preparation for Installing and Removing 6KPMs Be sure the power cord is unpluggedFigure 3.6.1b Magnum 6K16V, Top view without chassis cover Caution Be careful not to disturb the power supplyStep 2. Remove Chassis Cover Figure 3.6.1a Removing the Front panel from the unitFig 3.6.2a Granddaughter Board shown separately 3.6.2 Installing 6KPM Cards in the Magnum 6K16VStep 3. Remove front panel face plate retaining screws Figure 3.6.1c Top View - 6KPM retaining screws hold Face Plateversion for 4 copper 10/100 ports Fig. 3.6.2c Daughter Board, top view ofFigure 3.6.2f Securely latching up 6KPM Cards into a Magnum 6K16V Fig. 3.6.2g Top View 6KPM Module installed inside a 6K16VStep 3. Remove 6KPM Card Caution Be sure the power cord is unplugged3.6.3 Removing 6KPM Cards firmly. Figure 3.6.3a Top View - 6 retaining s crews shown by arrowsEnlarged view of Magnum 6K16V Console Port area 3.7 Connecting a Management Console Terminal to Magnum 6K16VDB-9 Console port connector 3.7.1 RS-232 DB-9 Console Com port Serial port pin assignmentsAddress Learning 4.1 Switching Functionality4.0 OPERATION Filtering and ForwardingSpeed LED, ON when the speed is 100Mbps , OFF when the 4.3 Up-link Manual Switches set as = , for RJ-45 port onlyPower LED, ON when external power is applied to the unit Full / Half duplex LED, ON when the port is running fullAuto-negotiation per-port for 802.3u-compliant switches occurs when LXSC40 and the “Cable Loss” for 9/125 Single-mode is 0.2 dB/km LXSC70 4.6 Power Budget Calculations for Magnum 6K16V PM’s with Fiber Media4.5 Flow-control, IEEE 802.3x standard Km, fdx Magnum 6K16V Managed Fiber SwitchInstallation and User Guide 06/04 6KP4V5.2 6KPM Module Description 5.0 Introduction - Magnum 6K16V Managed Fiber Switch Port Modules5.1 Inspecting the Package and Product 5.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module connectors and configured ports are ST connectorsand configured as 10Mb Half-duplex by defaultRJMSC is also a Combo 6 Port mode SC-type connectors. Itmodule of the 6K16V Switch The Magnum 6KP6as 25+ Km see Power Budget, Section 6KP8-MTRJ “small-form-factor”5.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factor The functionality of this 100BASE-FX multi-mode 4 port module isThe Magnum 6KP8-45MT MTRJ connectors give an advantage5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX MTRJ Small-Form-Factor5.2.9 6KP8-RJ45 Twisted Pair, 10/100Mb 8-Port connecting to a hub or another switch Single-Mode Fiber port LC 5.2.11 GBIC-SXSC Gigabit fiber1000Mb, multi-mode SC Connector6KP8V 5.2.12 6KM-BLNK 5.2.11a GBIC-LXSC Gigabit fiber 1000Mb, multi-mode SC Connector6.1 Before Calling for Assistance 6.0 TROUBLESHOOTING6.3 Return Material Authorization RMA Procedure 6.2 When Calling for Assistance6.4 Shipping and Packaging Information No Problem FoundGarrettCom, Inc 213 Hammond Ave Fremont, CA Attn. Customer Service B2.0 -48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION B1.0 SPECIFICATIONS FOR MAGNUM 6K16V SWITCHES, DC POWERB4.0 6K16V’S -48V, 24, 125 OR 5VDC INSTALLATION B3.0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHESB5.0 OPERATION B4.1 UL Requirements for DC-powered unitsB7.0 TROUBLESHOOTING hooked up at the lastC3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION Power Supply Internal, 24VDC Dual-Source, model # Dual-Src-24VPower Supply Internal, 125VDC Dual-Source, model # Dual-Src-125V C5.0 INSTALLATION C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGNC7.0 OPERATION C5.1 UL RequirementsC6.0 ORDERING INFORMATION Example Magnum 6K16VR-48VDC