Gefen GTB-MHDMI1.3-441 user manual RS-232 Serial Control, RS-232 Settings

Page 16

RS-232 SERIAL CONTROL

5 4 3 2 1

1 2 3 4 5

9 8 7 6

6 7 8 9

Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the RS-232 serial interface

This feature allows for easy integration into automated systems capable of transmitting RS-232 commands. Please use the settings listed below to configure the RS-232 port of the user’s system.

Transmitting the appropriate numeric ASCII character will simulate key presses on the RMT-4IR remote control.

Binary Table

ASCII

RMT-4IR

Binary

 

Button

 

 

 

 

1

1

0011 0001

2

2

0011 0010

3

3

0011 0011

4

4

0011 0100

RS-232 Settings

 

Bits per second

19200

Data bits

8

Parity

None

Stop bits

1

Flow Control

None

13

Image 16
Contents Gefen GTB-MHDMI1.3-441Asking for Assistance Technical SupportTechnical Support Hours Write ToContents About Gefen Why GefenToolBox? GefenToolBox 4x1 Switcher for HdmiIntroduction How It WorksOperation Notes Features Hdmi 1.3 FeaturesGeneral Features Package IncludesPanel Layout Source Selector and Indicator LEDs Panel DescriptionsHow to Connect the GefenToolBox 4x1 Switcher for Hdmi Connecting and Operating Gefentoolbox 4X1 Switcher for HdmiHow to Operate the GefenToolBox 4x1 Switcher for Hdmi Automatic Switching Example 2 Routing Input source 3 to the Output displayIR Remote Control Unit Description Routing Sources to DisplaysInstalling the IR Remote Control Battery IR Remote Control Unit InstallationBattery Slot DIP Switches IR Remote Control Unit ConfigurationResolving IR Code Conflicts IR Remote Control Unit Operation Source RMT-4IR buttonUsing the IR Extender IR Extender Installation4x1 Switcher RS-232 Settings RS-232 Serial ControlCommand Description CommandsCommand V command displays the firmware version Changing the IR Channel Changing the IR channelWall Mounting Instructions Specifications 5V DCPage Page Page Rev A6 Nordhoff St., Chatsworth CA