GE 45606 manual Valid Values

Page 16

1.When Receiving a Z-Wave Dim Command - Parameter 7 (number of steps or levels)

- Parameter 8 (timing of the steps) - Length: 1 Byte

Valid Values:

Parameter 7 (default = 1) Valid Values: 1-99

Parameter 8 (default = 3) Valid Values: 1-255

2.Manual Control Dimming (pressing the Dimmer’s rocker) - Parameter 9 (number of steps or levels)

- Parameter 10 (timing of the steps) - Length: 1 Byte

Valid Values:

Parameter 9 (default = 1) Valid Values: 1-99

Parameter 10 (default = 3) Valid Values: 1-255

3.When Receiving an All-On or All-Off Command - Parameter 11 (number of steps or levels)

- Parameter 12 (timing of the steps) - Length: 1 Byte

Valid Values:

Parameter 11 (default = 1) Valid Values: 1-99

Parameter 12 (default = 3) Valid Values: 1-255

Ignore Start Level When Receiving Dim Commands Please note: Every “Dim” command includes a start level embedded in it.

The 45606 can be set to ignore the start level that is part of the dim command. Setting parameter 5 to a value of 0 will cause the 45606 to dim or brighten from the start level embedded in the command.

-Parameter No: 5

-Length: 1 Byte

-Valid Values = 0 or 1 (default 1)

Image 16
Contents Dimmer Switch Introduction Dimmer switch LED light Air gap switch Risk of Fire Risk of Electrical Shock Risk of Burns Wireless Range Type of Construction See diagram on next Single, Dual and Triple Gang Boxes White Shock Hazard Wire Connector / Combination Chart Observe Important Wiring InformationInstructions Air Gap Switch Key FeaturesBasic Operation Manual ControlPrimary controller’s instructions for details Advanced Operation LED IndicatorAll On/All Off Dim Rate Adjustments Invert SwitchLED Light Valid Values Restoring Factory Defaults WarrantyU2Z45606-7 FCCOperation is subject to the following two conditions Specifications Compliance with IC Rules and Regulations