GE 45606 manual LED Light, Invert Switch, Dim Rate Adjustments

Page 15

LED Light

When shipped from the factory, the LED on the 45606 is set to turn ON when the connected light is turned OFF. This allows the LED to indicate the switch’s location in a dark room. To make the LED turn ON when the light is turned ON, change parameter 3’s value to “1”.

-Parameter No: 3

-Length: 1 Byte

-Valid Values = 0 or 1 (default 0)

Invert Switch

If the dimmer switch is accidentally installed upside down with “On” at the bottom and “Off” at the top, the default On/Off rocker settings can be reversed by changing parameter 4’s value to “1”.

-Parameter No: 4

-Length: 1 Byte

-Valid Values = 0 or 1 (default 0)

Dim Rate Adjustments

Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. The timing of the steps can be adjusted in 10 millisecond intervals. As an example, the default setting for parameter 8 is “3”. This means that the lighting level will change every 30 milliseconds when the Dim Command is received. A value of 255 would mean that the level would change every

2.55seconds. Combined, the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum-to-minimum or minimum-to-maximum brightness levels.

Image 15
Contents Dimmer Switch Introduction Dimmer switch LED light Air gap switch Risk of Fire Risk of Electrical Shock Risk of Burns Wireless Range Type of Construction See diagram on next Single, Dual and Triple Gang Boxes White Shock Hazard Observe Important Wiring Information Wire Connector / Combination ChartInstructions Manual Control Air Gap SwitchKey Features Basic OperationPrimary controller’s instructions for details LED Indicator Advanced OperationAll On/All Off Invert Switch Dim Rate AdjustmentsLED Light Valid Values Warranty Restoring Factory DefaultsFCC U2Z45606-7Operation is subject to the following two conditions Compliance with IC Rules and Regulations Specifications