APPENDIX B

The 8X8 DVI Matrix uses RS-232 serial communication for access to a number of features. Please us this section for EDID storing, calling, and routing functions.

REMOTE FUNCTION

The remote functions are used to modify the setting of the product, such as: Input to output routing, EDID memory management etc. These functions are available only by the serial communications port.

Modify By Shortcut

Switching Command

First character indicates the output monitor. Second character indicates the input number.

Example: ‘A5’ routes input 5 to output monitor A

Matrix Status Command

The ‘M’ or ‘m’ command will return the current routing state.

Shortcut Routing Command

This command sets the matrix routing state according to a preset routing state. First character is ‘S’ or ‘s’, second character indicates the state that is set by

function #PSASRS or #MSASRS (please see page##)

Setting Function Menu

The ‘P’ or ‘p’ command will return the settings function menu.

Modify By Function

The syntax for each function is always the same. The ‘#” character is the start flag followed by the function name in capital letter and a space. The space tells the MCU that the function name is ending. Finally, the parameters required for each function are separated by a space and ending by the ‘\r’ character or “Enter”

Example: #FunctionName_param1_param2_param3_param4…\r

RMT-16-IR Address

This function set the remote channel that must match the GEFEN RMT-16-IR remote control.

#RMT_param1\r

Parameter

Value

1

[0:3]

19

Image 22
Contents 8x8 DVI Matrix Technical Support Hours Asking for AssistanceTechnical Support Write ToContents Gefen 8x8 DVI Matrix IntroductionGefen How It WorksOperation Notes Features Package Includes8X8 DVI Matrix Front Panel Layout 8X8 DVI Matrix Front Panel Descriptions Monitor A~H Selected Source 1~88X8 DVI Matrix Back Panel Layout Optional Remote Switching Ports 8X8 DVI Matrix Back Panel DescriptionsEXT-RMT-MATRIX-848 Panel Layout EXT-RMT-MATRIX-848 Panel Descriptions Direct Select ButtonsHow to Connect the 8x8 DVI Matrix Connecting and Operating the 8X8 DVI MatrixOperating the 8x8 DVI Matrix 8X8 DVI Matrix Remote Description & Operation Output Input Remote Button Display SourceRMT-16-IR IR Channel Configuration 8x8 DVI Matrix DIP Switches RMT-16-IR DIP SwitchesEXT-RMT-MATRIX-848 Remote Operation RMT-8-IR IR Channel Configuration RMT-8-IR DIP SwitchesRS232 Settings RS-232 Serial Control InterfaceNetwork Cable Wiring Diagram Pin ColorAppendix a Bank a Bank B Bank C Bank DDIP Switch Input Description For future implementation DIP Switch Monitor Description For future implementationModify By Shortcut Appendix BModify By Function DS Edid Store In Edid Bank DS Edid Store In Locals EdidEdid From Bank Store In Locals Edid Print Local Edid Route Input DDC To Local EdidPrint DS Edid Print Edid BankLoad Edid To Edid Bank Print Edid SettingLoad Edid To Locals Edid Set Output Pre EmphasisSet Current Matrix As Routing State Set Default SettingSet Preset Routing State Print Routing State TableSpecifications