APPENDIX B

Print EDID Setting

This function sends the EDID setting table to the serial port.

#PRSEEDID\r

Load EDID To Locals EDID

These functions will load an EDID file through the serial port and store it in any Input’s Local EDID.

#LOEDIDTOLO_param1_param2_param3[_param4][_param5][_param6]

[_param7][_param8][_param9][_param10]\r

Parameter

Name

Value

1

Semi echo mode

0

Full echo mode

1

 

2

EDID.bin file (256 bytes)

1

EDID.bin file (256 bytes)

2

 

3 (4-10 optionally)

INPUT

[1:8]

Load EDID To EDID Bank

This function loads and EDID through the serial port and store it in the EDID bank.

#LOEDIDTOBA_param1_param2\r

 

Parameter

 

Name

Value

1

 

Semi echo mode

0

 

 

Full echo mode

1

 

 

 

 

 

2

EDID.bin file (256 bytes)

1

 

EDID.bin file (256 bytes)

2

 

 

 

 

3

 

EDID bank offset

[1:7]

 

Set Output Pre Emphasis

 

 

 

 

 

This function will set output Pre Emphasis in db.

 

 

 

 

 

#PE_param1_param2\r

 

 

 

 

 

 

 

 

 

 

Parameter

 

Name

 

Value

 

 

1

 

MONITOR

 

[A:H]

 

 

2

 

Pre Emp level [db]

 

[0,2,4,6]

 

22

Image 25
Contents 8x8 DVI Matrix Technical Support Asking for AssistanceTechnical Support Hours Write ToContents Gefen IntroductionGefen 8x8 DVI Matrix How It WorksOperation Notes Package Includes Features8X8 DVI Matrix Front Panel Layout Monitor A~H Selected Source 1~8 8X8 DVI Matrix Front Panel Descriptions8X8 DVI Matrix Back Panel Layout 8X8 DVI Matrix Back Panel Descriptions Optional Remote Switching PortsEXT-RMT-MATRIX-848 Panel Layout Direct Select Buttons EXT-RMT-MATRIX-848 Panel DescriptionsHow to Connect the 8x8 DVI Matrix Connecting and Operating the 8X8 DVI MatrixOperating the 8x8 DVI Matrix Output Input Remote Button Display Source 8X8 DVI Matrix Remote Description & Operation8x8 DVI Matrix DIP Switches RMT-16-IR DIP Switches RMT-16-IR IR Channel ConfigurationEXT-RMT-MATRIX-848 Remote Operation RMT-8-IR DIP Switches RMT-8-IR IR Channel ConfigurationRS-232 Serial Control Interface RS232 SettingsPin Color Network Cable Wiring DiagramBank a Bank B Bank C Bank D Appendix aDIP Switch Monitor Description For future implementation DIP Switch Input Description For future implementation Modify By Shortcut Appendix B Modify By Function DS Edid Store In Edid Bank DS Edid Store In Locals EdidEdid From Bank Store In Locals Edid Print DS Edid Route Input DDC To Local EdidPrint Local Edid Print Edid BankLoad Edid To Locals Edid Print Edid SettingLoad Edid To Edid Bank Set Output Pre EmphasisSet Preset Routing State Set Default SettingSet Current Matrix As Routing State Print Routing State TableSpecifications