8.As shown in Figure 20, use the S19 window to specify which S19 file to store active NVM data to and then click the “OK” button. For NVM0 use ‘PD_NVM0.s19’ and for NVM1 use ‘PD_NVM1.s19’.
Figure 20 S19 File Window
9.Close “Programmer Expert” window.
10.Use the PC tool “Production_Data_Converter.exe” to convert the production data in NVM to default NVM sector NVM0. Copy the “Production_Data_Converter.exe” tool to the folder that contains the PD_NVM0.s19 and PD_NVM1.s19 files. Execute the ‘Production_Data_Converter.exe’. The output is an PD_NVM.s19 file containing the production data from the active NVM sector.
NOTE
The “Production_Data_Converter.exe” tool can be found in the EVK release
“EVK_3_0B” in folder .\source\Zigbee_EVK\EVK_Common\CPROG_Tool\Scripts\
11.Click on “Load Application” under the “File” menu to open the “Load Executable File” window. Specify the application file to program using the “Load Executable” window as shown in Figure 21. Select the “Motorola
Figure 21 Load Executable File Window
Embedded Bootloader Reference Manual, Rev 0.0 | Freescale Semiconductor |