4. Troubleshooting
Problems | Possible cause and remedy |
|
|
14.Noise appears on the screen. | • When entering the signals of analog input, select 1 to |
| 4 in <Signal Filter> from the <Screen> menu to change |
| the mode. |
| • When entering the signals of HDCP system, the normal |
| images may not be displayed immediately. |
|
|
15.The <Smoothing> icon on the Adjustment menu | • <Smoothing> is disabled when the screen is displayed in |
<Screen> cannot be selected. | the following resolutions. |
| •1920 × 1200 |
| •Select "Enlarged" during <Screen Size> in the |
| resolution of 800 × 600 |
| •Select "Enlarged" during <Screen Size> in the |
| resolution of 1600 × 1200 |
| •Select "Normal" during <Screen Size> mode. |
16.The Main menu of Adjustment menu does not start. | • Check for Adjustment Lock function (page 22). |
|
|
17.The FineContrast mode is not displayed. | • Check whether the Main menu of Adjustment menu is |
| displayed (page 13). |
| • Check for Adjustment Lock function (page 22). |
|
|
18. does not function. | • does not function when digital signal is input. |
| • Check for Adjustment Lock function (page 22). |
|
|
19.PC is hung up. / The peripherals connected to the | • Check that the USB cable is correctly connected. |
downstream ports do not operate. | • Check the downstream ports by connecting the |
| peripherals to other downstream ports. If the problem is |
| solved by doing this, contact an EIZO dealer. (For details, |
| refer to the manual of the PC.) |
| • Try executing the following method. |
| •Restarting the PC |
| •Connecting the PC and peripherals directly |
| If the problem is solved by doing this, contact an EIZO |
| dealer. |
20.USB function cannot be setup. | • Check that the USB cable is correctly connected. |
| • Check that the PC and OS are USB compliant. (For |
| verification of USB support, consult the manufacturer of |
| each system.) |
| • Check the PC's BIOS setting for USB. (For details, refer |
| to the manual of the PC.) |
28