Falcon F1000, F3400 manual Unit Start Up, Flash Executable Code

Page 64

5EIA-232 Interface

2Set the appropriate COM Port to 9600 baud, NO parity, 8 data bits, 1 stop bit, (9600/N/8/ 1), and no software or hardware flow control.

Figure 5.2 Com1 Properties Screen

3Once the terminal emulation software starts, press Enter on the keyboard and the Main Menu should appear. If the Main Menu does not appear, check the communication settings and make sure the unit is powered on.

5.1.Unit Start Up

When the unit is powered up, diagnostic tests are performed and the Flash Program code is verified. The main system code is executed after a 10 second delay. During the boot up sequence, the System Status LED will flash at a rapid rate of 10 flashes per second. If the System Status LED continues to flash for more then twenty seconds, there is a fault with the unit and service is required.

5.2.Flash Executable Code

After the bootup sequence, the main program executes from Flash memory. In order to run properly, the unit must have a unique MAC address (assigned by the manufacturer) and an IP address. The factory default for the IP address is 10.0.0.186. If the unit is connected to the enterprise’s network, an IP address must be obtained from the network administrator. The F3400/F1000 must be reconfigured with this new IP address. This reconfiguration can be done in the field. See the Configuration Menu, menu number 1. Once the system reaches this point, press Enter to display the System Main Menu.

www.rletech.com

64

970.484.6510

Image 64
Contents Monitoring & Notification Revision History Product Registration Rletech.com 970.484.6510 Contents Remote Access Alarm ID Reference Tables Rletech.com Figures F3400/F1000 Accessories Wiring Tables Rletech.com System Overview Product DescriptionFront Panel Indicators and Controls System Status LEDTerminal Block Designations System Overview Terminal Block Designations Rear Panel Indicators SW1 Switch SettingsInstallation Getting StartedCommunication Set the F3400/F1000’s IP AddressObtain the Ethernet Address Set the F3400/F1000’s IP Address using a Web Browser Troubleshooting the ARP/PING CommandsSet the F3400/F1000’s IP Address Using an EIA232 Connection Set the F3400/F1000s IP Address using a Telnet ConnectionF3400/F1000 Wiring Power Supply and Ground Connections2 EIA232 COM1 Connection 3 RJ11 Phone Line Connection4 RJ45 Ethernet Connection F3400/F1000 Ethernet Connection to a PC on a SubnetF3400/F1000 Relay Output Wiring Examples Relay K1 and K2 ConnectionF3400/F1000 Web Interface Overview Main MenuAlarm History Historical DataEvent History Digital Status History Data History Data History Text Downloads Identity Server StatusConfiguration Web LinksConfiguration Menu Configuration MenuInputs Configuration InputsCalculator Link Configuration Menu Example Relays Configuration RelaysSchedules Configuration Menu SchedulesAlarm Management Modem Configuration ModemConfigure Phone Numbers Phone Number ConfigurationConfiguration Menu Configuring Web Links Egg/Nest Falcon LinksSNMP/SYSLOG 13 Modbus Interface Configuration Modbus InterfaceLD Unit Modbus Slave Configuration 14 LD Unit Modbus Slave ConfigurationModbus Register Data Log Modbus Packet LogReset Modbus Port Series Modbus Slave Register Map17 BACnet Configuration BACnet18 Server Ping Configuration Server Ping19 System Configuration SystemClock Internet ProtocolUser Administration Web Access 22 User Administration Configuration23 Email Configuration 24 Network Time Protocol Configuration Network Time ProtocolNetwork Statistics Flash ProgramProduct Registration Configuration Menu 970.484.6510 EIA-232 Interface Unit Start Up Flash Executable CodeInformation regarding the commands in this section Main Configuration Menu SC Configuration Menu Factory MenuIP Configuration Menu TCPIP Configuration Menu Commands Remote Access Remote Access Configuration Modem OptionDisplay Date/Time TI ADC Input Values AD Configuring the F3400/F1000 POINT-TO-POINT ProtocolConfiguring the PC Upgrading Firmware Managing Configuration Data Upgrading F3400/F1000 FirmwareUpgrading F3400/F1000 Firmware via Tftp Client Port =Upgrading Firmware and Managing Configuration Data Saving Configuration Data via Tftp Client Loading/Saving F3400/F1000 Configuration DataSaving Configuration Data via EIA232 COM1 Port X- Modem Loading Configuration Data via Tftp Client Loading Configuration Data via EIA232 COM1 Port X-ModemPage Analog Input 4-20MA Reference Chart Analog 4-20Ma Gain/Offset Conversion FormulaVoltage F3400/F1000 Accessories Wiring Figure B.1 T120D Temperature SensorsFigure B.3 Dwyer Temperature/Humidity Sensors Figure B.6 HD150 & HD150-2 Gas Sensors Configuring the SeaHawk LD5100 as an Analog Input Figure B.11 SeaHawk LDRA6, LD1000, and LD300 Leak DetectionF3400/F1000 Accessories Wiring F3400/F1000 Accessories Wiring 970.484.6510 Alarm ID Reference Tables Analog TablesThermistor Tables Digital Tables Alarm ID Reference Tables 970.484.6510 Technical Specifications F3400HTTP/HTML Front Panel Interface Switches Technical Specifications 970.484.6510