If necessary, the SH612 can distribute synchronization signals via four AES Sync (AES/EBU), Word Clock, video, or MTC outputs to System 5/Max Air components. The SH612 can generate or lock to Time code, or convert between different formats. All standard time code rates are supported:
•Film: 24 fps
•PAL/SECAM: 25 fps
•Color NTSC: 29.97 (drop and
•black and white video rate
•MIDI sequencers: 30 fps (drop and
NOTE: Euphonix does not recommend using the SH612 for synchronization distribution. System 5 and Max Air installations should use synchronization distribution amplifiers with separate sync lines going to each component (no looping). Please see the syn- chronization notes in your console’s install guide.
The SH612 routes digital audio via 12 MADI In and 12 MADI Out ports, each with the capacity to receive or transmit up to 56 channels (up to
The MADI spec allows 64 channels of audio per port - however, Euphonix’ VariSpeed technology occupies some of this bandwidth and thus each port supports 56 channels at
48 kHz.
1.1.2Power On Sequence
Attach the provided
We recommend powering up the SH612 before the digital devices to which it is con- nected. The SH612 conducts a brief
NOTE: For console installations, please refer to the power up routine for System 5/Max Air- before attempting to power the DF64 Digital Frames and the Pilot Computers.