Euphonix SH612 Studio Hub User Guide | Integration With Jupiter VM3000 Routers |
|
|
|
|
5.When finished entering all inputs, click Apply and Close.
6.Save the configuration set.
4.2.4Switcher Output
1.If you have multiple switchers, select
This displays a dialog to choose which switcher to edit.
2.Click the switcher added in Switcher Description above to describe the SH612.
3.Press OK.
The Switcher Output dialog opens.
Figure 4-4 Jupiter Switcher Output dialog
4.Enter each SH612 output device on a separate row. For each output, enter the physical outputs for each level corresponding to their outputs on the SH612.
Note again that outputs start at 000 so output 1 on MADI port 1 is output 000 on the Jupiter and output 1 on MADI port 2 is output 064 on the Jupiter. There are no matching outputs on the SH612 for Jupiter outputs
NOTE: The Security,
5.When finished entering all outputs, click Apply and then Close.
6.Save the configuration set.
29