Z8 Encore!® Flash Microcontroller Development Kit
User Manual
Table 10. J7 External Vref
25
Shunt Status Function | Device or Register Affected | |
IN | External Vref is used for ADC | Internal Vref is disabled. |
OUT | Internal Vref is used for ADC | Internal Vref is enabled. |
Table 11. J9 Vref
| Function | Device or Register Affected |
Test point to external Vref | Vref | |
|
|
|
GND | None | |
|
|
|
Table 12. J10 IrDA Enable/Disable
Shunt Status | Function | Device Affected |
IN | IrDA enabled | Only the IrDA interface is operational. |
|
|
|
OUT | IrDA disabled | UART0 communicates through |
|
| If J6 |
|
| assigned to other functions (console |
|
| connector P1 is disabled). |
|
| If J6 |
|
| is enabled (Port A |
|
| UART0). |
|
|
|
Note: If the IrDA board is installed the Console port is disabled.
Z8 Encore!® Evaluation Board |