DeWalt R510 manual Mixed SAS +, Must be all HDDs Ex. Min SAS +, Mixed SSD +

Page 59

Dell

 

 

 

 

 

 

 

 

 

Mixed SAS +

 

 

 

 

 

 

 

 

 

 

SATA

 

 

 

 

 

 

 

 

 

 

 

(Must be all

 

 

 

 

 

 

 

 

 

 

3.5" HDDs)

 

 

 

 

 

 

 

 

 

 

(ex. Min 2x

 

 

 

 

 

 

 

 

 

 

SAS + 2x

 

 

 

 

 

 

 

 

 

 

SATA;

 

 

 

 

 

 

 

 

 

 

 

Max 2x SAS

 

 

R510-8 Mixed HDD (SAS + SATA) Factory Configuration

+ 6 SATA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

 

Max

 

 

Type

 

#

 

 

Name

 

Description

HDD

 

HDD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mix

 

 

 

 

 

 

 

 

 

2 +

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

 

 

ASS-X

 

No RAID (SAS 6/iR, PERC H200)

2 + 2

 

6

 

 

HDD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 +

 

 

(Add-

 

 

 

 

 

 

 

 

 

 

 

 

33

 

 

ASSR1/R1-X

 

RAID1+RAID1 (SAS 6/iR, PERC H200, PERC 6/i, PERC H700)

2 + 2

 

2

 

 

in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

card)

 

 

 

 

 

 

 

 

 

2 +

 

 

 

 

34

 

 

ASSR1/R5-X

 

RAID1 + RAID5 (PERC 6/i, PERC H700)

2 + 3

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 +

 

 

 

 

35

 

 

ASSR5/R10-X

 

RAID5 + RAID10 (PERC 6/i, PERC H700)

4 + 4

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mixed SSD +

 

 

 

 

 

 

 

 

 

 

SAS

 

 

 

 

 

 

 

 

 

 

 

(Must be all

 

 

 

 

 

 

 

 

 

 

2.5" HDDs)

 

 

 

 

 

 

 

 

 

 

(ex. Min 2x

 

 

 

 

 

 

 

 

 

 

SSD + 2x

 

 

 

 

 

 

 

 

 

 

SAS;

 

 

 

 

 

 

 

 

 

 

 

Max 2x SSD

 

 

R510-8 Mixed HDD (SSD + SAS) Factory Configuration

+ 6 SAS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

 

Max

 

 

Type

 

#

 

 

Name

 

Description

HDD

 

HDD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mix

 

 

 

 

 

 

 

 

 

2 +

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36

 

 

ASS-X

 

No RAID (PERC H200)

2 + 2

 

6

 

 

HDD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 +

 

 

(Add-

 

 

 

 

 

 

 

 

 

 

 

 

37

 

 

ASSR1/R1-X

 

RAID1+RAID1 (PERC H200, PERC 6/i, PERC H700)

2 + 2

 

2

 

 

in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

card)

 

 

 

 

 

 

 

 

 

2 +

 

 

 

 

38

 

 

ASSR1/R5-X

 

RAID1 + RAID5 (PERC 6/i, PERC H700)

2 + 3

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 +

 

 

 

 

39

 

 

ASSR5/R10-X

 

RAID5 + RAID10 (PERC 6/i, PERC H700)

4 + 4

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PowerEdge R510 Technical Guide

59

Image 59
Contents Dell Product Name PowerEdge R510 Technical Guide Table of Contents Bios Tables Figures Product Description OverviewPage Product Comparison Comparison of PowerEdge Server FeaturesDiagnostic LCD 1Intel Xeon Processor 5500 and 5600 Series New TechnologiesDetailed Information Sparing3Next Generation Dell Embedded Server Management 1PCIe Generation2DDR3 Memory Technology System Overview Product Features SummaryHxWxD HDD/SSD Microsoft DatabaseVirtualization Dell Chassis Description Dimensions and WeightMechanical System Dimensions PowerEdge R510-4 HDD Configuration Front Panel View and Features2System ID Button 3Power Button/Power LED1NMI Button USB Controller Priorities 4Video Connector Rack Systems5USB Connectors Power Button Behavior under ACPI/Non-ACPI Operating Systems8Key Lock 6DVD/CD7Hard Drive Activity LED With Redundant Power Supply for PowerEdge R510-8 Back Panel View and FeaturesLeft Side View Redundant PSUInternal Chassis Views Battery HolderPowerEdge R510-12 Internal View ReadyRails Static Rails for 4-post & 2-post Racks support ReadyRails Sliding Rails for 4-post Racks dimensionsRails and Cable Management ReadyRailsTM Sliding Rails for 4-post Racks supportR510 Sliding Rails with CMA R510 Sliding Rails without CMA1Fan module FansFan Module for R510-4 2Fan Location and InstallationFan Location Fan Connector LocationsCabling Information CablingSecurity Bezel LockTop Cover Intrusion SwitchUSB Key Hard Drive SecurityField Replaceable Units FRU BatteryPower Supplies Power, Thermal, AcousticThermal Environmental SpecificationsOperating/Non-Operating Storage Requirements Maximum Input AmpsEnergy Star Compliance Acoustics Acoustics of 12-HDD Chassis Acoustics of 4-HDD ChassisAcoustics of 8-HDD Chassis Definitions Supported Processors ProcessorsMirroring MemoryOverview DIMMs Supported2System Memory Interface Intel 5500 Chipset FeaturesChipset 1Intel QuickPath InterconnectIntel ICH10R South Bridge Bios Support BiosAcpi ConfigurationPower Management Summary of Power Management Features Power Management State Transition Supported Power ProfilesUefi and Acpi Supported CPU Acpi States/Turbo ModeQDF# UefiUefi is Uefi is not Uefi SummarySlot Location Bandwidth Physical Slot Height Length 10 I/O SlotsRiser 1 Detail Riser 1 Slot InformationRiser 2 Detail Boot Order for RiserPCI Card Dimensions PCI Card Dimensions RiserBandwidth Slot Location Height Length Riser 2 Slot InformationDrives StorageNo Mixed RAID ConfigurationsRaid Configurations for the PowerEdge R510-4 HDD PowerEdge R510-4 Factory ConfigurationAdd Card Raid Configurations for the PowerEdge R510-8Add CardMixed SSD + Mixed SAS +Must be all HDDs Ex. Min SAS + MixR51012 Mixed HDD SAS + Sata Factory Configuration RAID Configuration for PowerEdge R510-12Factory Configuration SAS R510-12 Mixed HDD SSD + SAS Factory ConfigurationMin Max Type Name Description Factory ConfigurationR510-12 Mixed HDD Hot-swap 3.5 SAS + Hot-swap 3.5 Sata + internal 2.5 SASTape Drives Optical DrivesVideo Microsoft Operating Systems Supported Operating SystemsLinux Operating Systems Operating Systems Version Factory Install Logo/CertSupported Virtualization Operating Systems VirtualizationEmbedded Server Management Systems ManagementServer Management IDRAC6 Express Lifecycle Controller and Unified Server ConfiguratorUnified Server Configurator Features and Description Feature DescriptionIDRAC6 Enterprise Features List for BMC, iDRAC6, and vFlashPowerEdge R510 Technical Guide FeatureDell External Storage PeripheralsUSB peripherals Packaging Options Single Pack Dimensions and WeightsAppendix a R510 Volatility Tables PowerEdge R510 VolatilityIDRAC6 Enterprise TPM ID Eeprom Volatility Data Writing and PurposeBackplane firmware HDD status, etc How is data input to this memory? Planar Methodology for Data Input to MemoryControl Panel Power SupplyHow is data input to this memory? Chipset BackplaneRAM Methodology for Memory and ClearingPlanar Nvramclr jumper or Remove AC cord, remove cover SAS 6/iR Integrated