DeWalt R510 manual Methodology for Data Input to Memory, How is data input to this memory? Planar

Page 78

Dell

Table 35. Methodology for Data Input to Memory

 

 

 

How is data input to this memory?

 

 

 

 

 

 

 

 

 

 

Planar

 

 

 

 

 

 

 

 

 

System BIOS SPI Flash

 

 

Loading flash memory requires a vendor-provided firmware file and loader program which is

 

 

 

 

 

 

executed by booting up the system from a floppy or OS-based executable containing the

 

 

 

firmware file and the loader. System loaded with arbitrary data in firmware memory will not

 

 

 

operate.

 

 

 

 

LOM Configuration

 

 

Loading flash memory requires a vendor-provided firmware file and loader program which is

Data

 

 

executed by booting the system from a floppy or OS-based executable containing the

 

 

 

firmware file and the loader. LOMs loaded with arbitrary data in firmware memory will not

 

 

 

operate.

 

 

 

 

 

iDRAC6 Controller

 

 

 

 

ROM

 

 

N/A

 

 

 

 

 

iDRAC6 controller

 

 

 

 

RAM

 

 

iDRAC embedded system

 

 

 

 

 

 

 

System CPLD

 

 

Loading flash memory requires a vendor-provided firmware file and loader program which is

 

 

 

executed by booting the system from a floppy or OS-based executable (currently only DRMK

 

 

 

utility support) containing the firmware file and the loader. A system loaded with arbitrary

 

 

 

data in CPLD memory will not operate.

 

 

 

 

System CPLD

 

 

Not used

 

 

 

 

iDRAC6 Express

 

 

iDRAC OS: Loading flash memory requires a vendor-provided firmware file and loader program

Internal Flash

 

 

which is executed by booting the system from a floppy or OS-based executable containing the

 

 

 

firmware file and the loader. System loaded without a good iDRAC firmware image yields a

 

 

 

non-functional iDRAC.

 

 

 

Managed Services Repository: Various partitions are loaded via vendor-provided firmware file

 

 

 

and loader program just like iDRAC OS.

 

 

 

 

System RAM

 

 

System OS

 

 

 

 

 

TPM ID EEPROM (Plug

 

 

 

 

in module only)

 

 

Factory load only

 

 

 

 

 

TPM Binding EEPROM

 

 

 

 

(on China planar

 

 

 

 

only)

 

 

BIOS only

 

 

 

 

 

iDRAC6 SDRAM

 

 

Embedded iDRAC OS for 108MB and 8MB for VGA frame buffer

 

 

 

 

 

 

 

iDRAC6 FRU

 

 

Factory and iDRAC embedded OS

 

 

 

 

iDRAC6 Boot Block

 

 

Loading flash memory requires a vendor-provided firmware file and loader program which is

Flash

 

 

executed by booting the system from a floppy or OS-based executable or out-of-band

 

 

 

firmware updates across the management network. Bad content makes the iDRAC inoperable

 

 

 

and is unrecoverable in the customer environment. The lifecycle log is automatically updated

 

 

 

by the iDRAC as various system component firmware, hardware, and software versions are

 

 

 

changed.

 

 

 

 

 

Trusted Platform

 

 

 

 

Module

 

 

Using TPM-enabled operating systems

 

 

 

 

 

 

 

 

78

 

PowerEdge R510 Technical Guide

Image 78
Contents Dell Product Name PowerEdge R510 Technical Guide Table of Contents Bios Tables Figures Overview Product DescriptionPage Comparison of PowerEdge Server Features Product ComparisonDiagnostic LCD Sparing New TechnologiesDetailed Information 1Intel Xeon Processor 5500 and 5600 Series1PCIe Generation 2DDR3 Memory Technology3Next Generation Dell Embedded Server Management Product Features Summary System OverviewHxWxD HDD/SSD Database VirtualizationMicrosoft Dell Dimensions and Weight MechanicalChassis Description System Dimensions Front Panel View and Features PowerEdge R510-4 HDD Configuration3Power Button/Power LED 1NMI Button2System ID Button Power Button Behavior under ACPI/Non-ACPI Operating Systems 4Video Connector Rack Systems5USB Connectors USB Controller Priorities6DVD/CD 7Hard Drive Activity LED8Key Lock Back Panel View and Features With Redundant Power Supply for PowerEdge R510-8Redundant PSU Left Side ViewBattery Holder Internal Chassis ViewsPowerEdge R510-12 Internal View ReadyRailsTM Sliding Rails for 4-post Racks support ReadyRails Sliding Rails for 4-post Racks dimensionsRails and Cable Management ReadyRails Static Rails for 4-post & 2-post Racks supportR510 Sliding Rails without CMA R510 Sliding Rails with CMAFans 1Fan module2Fan Location and Installation Fan Module for R510-4Fan Connector Locations Fan LocationBezel Lock CablingSecurity Cabling InformationHard Drive Security Intrusion SwitchUSB Key Top CoverBattery Field Replaceable Units FRUPower, Thermal, Acoustic Power SuppliesEnvironmental Specifications ThermalMaximum Input Amps Energy Star ComplianceOperating/Non-Operating Storage Requirements Acoustics Acoustics of 4-HDD Chassis Acoustics of 8-HDD ChassisAcoustics of 12-HDD Chassis Definitions Processors Supported ProcessorsDIMMs Supported MemoryOverview Mirroring1Intel QuickPath Interconnect Intel 5500 Chipset FeaturesChipset 2System Memory InterfaceIntel ICH10R South Bridge Bios Bios SupportConfiguration Power ManagementAcpi Summary of Power Management Features Supported Power Profiles Power Management State TransitionSupported CPU Acpi States/Turbo Mode Uefi and AcpiUefi QDF#Uefi Summary Uefi is Uefi is notRiser 1 Slot Information 10 I/O SlotsRiser 1 Detail Slot Location Bandwidth Physical Slot Height LengthPCI Card Dimensions Riser Boot Order for RiserPCI Card Dimensions Riser 2 DetailRiser 2 Slot Information Bandwidth Slot Location Height LengthStorage DrivesHDD PowerEdge R510-4 Factory Configuration RAID ConfigurationsRaid Configurations for the PowerEdge R510-4 No MixedCard Raid Configurations for the PowerEdge R510-8Add Add CardMix Mixed SAS +Must be all HDDs Ex. Min SAS + Mixed SSD +RAID Configuration for PowerEdge R510-12 Factory ConfigurationR51012 Mixed HDD SAS + Sata Factory Configuration R510-12 Mixed HDD SSD + SAS Factory Configuration SASHot-swap 3.5 SAS + Hot-swap 3.5 Sata + internal 2.5 SAS Factory ConfigurationR510-12 Mixed HDD Min Max Type Name DescriptionOptical Drives Tape DrivesVideo Operating Systems Microsoft Operating Systems SupportedOperating Systems Version Factory Install Logo/Cert Linux Operating SystemsVirtualization Supported Virtualization Operating SystemsSystems Management Server ManagementEmbedded Server Management Feature Description Lifecycle Controller and Unified Server ConfiguratorUnified Server Configurator Features and Description IDRAC6 ExpressFeature Features List for BMC, iDRAC6, and vFlashPowerEdge R510 Technical Guide IDRAC6 EnterpriseDell Peripherals USB peripheralsExternal Storage Single Pack Dimensions and Weights Packaging OptionsPowerEdge R510 Volatility Appendix a R510 Volatility TablesIDRAC6 Enterprise Volatility Data Writing and Purpose TPM ID EepromBackplane firmware HDD status, etc Methodology for Data Input to Memory How is data input to this memory? PlanarBackplane Power SupplyHow is data input to this memory? Chipset Control PanelMethodology for Memory and Clearing RAMPlanar Nvramclr jumper or Remove AC cord, remove cover SAS 6/iR Integrated