DeWalt R510 manual Methodology for Memory and Clearing, Ram

Page 80

Dell

SAS 6/iR Integrated

Controller

Loading flash memory requires a vendor-provided firmware file and loader program which is

Configuration

executed by booting the system from a floppy or OS-based executable (DUPs, Unified Server

Data

Configurator) containing the firmware file and the loader. Storage adapters loaded with bad

 

firmware will not provide storage controller behavior.

 

 

FRU

Factory only. Not customer updatable.

 

 

 

Integrated

 

Mirroring NVSRAM

Embedded storage firmware controls this data

 

 

iDRAC6 Enterprise

 

 

 

vFlash

Preloaded media before installation, or remote out-of-band upload of user data (i.e., ISO images,

 

files) or local server read/write capability to use like a hard disk.

 

 

Table 36. Methodology for Memory and Clearing

 

 

How is this memory write

 

 

 

 

 

 

 

 

 

 

protected?

 

 

How is the memory cleared?

 

 

 

 

 

 

Planar

 

 

 

 

 

 

 

 

 

 

 

System BIOS SPI Flash

 

 

 

 

Not possible with any utilities or applications and system is not

 

 

Software write protected

 

functional if corrupted/removed.

 

 

 

 

 

LOM Configuration

 

Not explicitly protected

 

 

Data

 

but special applications

 

 

 

 

are needed to

 

 

 

 

communicate through the

 

 

 

 

LOMs to reprogram this

 

 

 

 

ROM.

 

Not user-clearable

 

 

 

 

 

iDRAC6 Controller

 

protected permanently by

 

 

ROM

 

hardware

 

Not clearable

 

 

 

 

 

 

iDRAC6 controller

 

 

 

 

 

RAM

 

n/a

 

iDRAC reset

 

 

 

 

 

 

 

 

 

System CPLD

 

Requires special system

 

Not possible with any utilities or applications and system is not

 

 

 

 

 

specific utility

 

functional if corrupted/removed.

 

 

 

 

 

System CPLD

 

Not accessible

 

Not clearable

 

 

 

 

 

iDRAC6 Express

 

Writes are proxied through

 

 

Internal Flash

 

a temporary iDRAC

 

 

 

 

scratchpad RAM and not

 

 

 

 

directly made from an OS

 

 

 

 

or OS application.

 

Not user-clearable

 

 

 

 

 

System RAM

 

OS control

 

Reboot or power down system

 

 

 

 

 

 

TPM ID EEPROM (Plug

 

 

 

 

 

in module only)

 

HW read only

 

Not - read only

 

 

 

 

 

TPM Binding EEPROM

 

Locked by BIOS from

 

 

(on China planar

 

physical access by anyone

 

 

only)

 

after boot

 

N/A - BIOS control only

 

 

 

 

 

 

80

PowerEdge R510 Technical Guide

Image 80
Contents Dell Product Name PowerEdge R510 Technical Guide Table of Contents Bios Tables Figures Overview Product DescriptionPage Comparison of PowerEdge Server Features Product ComparisonDiagnostic LCD New Technologies Detailed InformationSparing 1Intel Xeon Processor 5500 and 5600 Series3Next Generation Dell Embedded Server Management 1PCIe Generation2DDR3 Memory Technology Product Features Summary System OverviewHxWxD HDD/SSD Microsoft DatabaseVirtualization Dell Chassis Description Dimensions and WeightMechanical System Dimensions Front Panel View and Features PowerEdge R510-4 HDD Configuration2System ID Button 3Power Button/Power LED1NMI Button 4Video Connector Rack Systems 5USB ConnectorsPower Button Behavior under ACPI/Non-ACPI Operating Systems USB Controller Priorities8Key Lock 6DVD/CD7Hard Drive Activity LED Back Panel View and Features With Redundant Power Supply for PowerEdge R510-8Redundant PSU Left Side ViewBattery Holder Internal Chassis ViewsPowerEdge R510-12 Internal View ReadyRails Sliding Rails for 4-post Racks dimensions Rails and Cable ManagementReadyRailsTM Sliding Rails for 4-post Racks support ReadyRails Static Rails for 4-post & 2-post Racks supportR510 Sliding Rails without CMA R510 Sliding Rails with CMAFans 1Fan module2Fan Location and Installation Fan Module for R510-4Fan Connector Locations Fan LocationCabling SecurityBezel Lock Cabling InformationIntrusion Switch USB KeyHard Drive Security Top CoverBattery Field Replaceable Units FRUPower, Thermal, Acoustic Power SuppliesEnvironmental Specifications ThermalOperating/Non-Operating Storage Requirements Maximum Input AmpsEnergy Star Compliance Acoustics Acoustics of 12-HDD Chassis Acoustics of 4-HDD ChassisAcoustics of 8-HDD Chassis Definitions Processors Supported ProcessorsMemory OverviewDIMMs Supported MirroringIntel 5500 Chipset Features Chipset1Intel QuickPath Interconnect 2System Memory InterfaceIntel ICH10R South Bridge Bios Bios SupportAcpi ConfigurationPower Management Summary of Power Management Features Supported Power Profiles Power Management State TransitionSupported CPU Acpi States/Turbo Mode Uefi and AcpiUefi QDF#Uefi Summary Uefi is Uefi is not10 I/O Slots Riser 1 DetailRiser 1 Slot Information Slot Location Bandwidth Physical Slot Height LengthBoot Order for Riser PCI Card DimensionsPCI Card Dimensions Riser Riser 2 DetailRiser 2 Slot Information Bandwidth Slot Location Height LengthStorage DrivesRAID Configurations Raid Configurations for the PowerEdge R510-4HDD PowerEdge R510-4 Factory Configuration No MixedRaid Configurations for the PowerEdge R510-8 AddCard Add CardMixed SAS + Must be all HDDs Ex. Min SAS +Mix Mixed SSD +R51012 Mixed HDD SAS + Sata Factory Configuration RAID Configuration for PowerEdge R510-12Factory Configuration R510-12 Mixed HDD SSD + SAS Factory Configuration SASFactory Configuration R510-12 Mixed HDDHot-swap 3.5 SAS + Hot-swap 3.5 Sata + internal 2.5 SAS Min Max Type Name DescriptionOptical Drives Tape DrivesVideo Operating Systems Microsoft Operating Systems SupportedOperating Systems Version Factory Install Logo/Cert Linux Operating SystemsVirtualization Supported Virtualization Operating SystemsEmbedded Server Management Systems ManagementServer Management Lifecycle Controller and Unified Server Configurator Unified Server Configurator Features and DescriptionFeature Description IDRAC6 ExpressFeatures List for BMC, iDRAC6, and vFlash PowerEdge R510 Technical GuideFeature IDRAC6 EnterpriseDell External Storage PeripheralsUSB peripherals Single Pack Dimensions and Weights Packaging OptionsPowerEdge R510 Volatility Appendix a R510 Volatility TablesIDRAC6 Enterprise Volatility Data Writing and Purpose TPM ID EepromBackplane firmware HDD status, etc Methodology for Data Input to Memory How is data input to this memory? PlanarPower Supply How is data input to this memory? ChipsetBackplane Control PanelMethodology for Memory and Clearing RAMPlanar Nvramclr jumper or Remove AC cord, remove cover SAS 6/iR Integrated