Cypress CY62146E MoBL manual Data Retention Characteristics, Parameters Unit

Page 4

CY62146E MoBL

R1

VCC

OUTPUT

30 pF

INCLUDING

JIG AND

SCOPE

Figure 2. AC Test Loads and Waveforms

 

 

 

 

 

 

 

 

VCC

 

 

 

 

 

 

 

 

ALL INPUT PULSES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90%

 

 

 

10%

 

 

 

 

 

 

90%

 

 

 

 

 

 

 

10%

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fall Time = 1 V/ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R2 Rise Time = 1 V/ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Equivalent to: THÉVENIN EQUIVALENT

 

 

 

 

 

 

 

 

 

 

 

 

 

RTH

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

V TH

 

 

 

 

 

 

 

 

 

 

Parameters

5.0V

Unit

R1

1800

Ω

 

 

 

R2

990

Ω

 

 

 

RTH

639

Ω

VTH

1.77

V

Data Retention Characteristics

Over the Operating Range

 

Parameter

Description

 

 

Conditions

Min

Typ[2]

Max

Unit

VDR

VCC for Data Retention

 

 

 

2

 

 

V

 

[6]

 

 

 

 

 

 

 

 

 

Data Retention Current

VCC = 2V, CE > VCC – 0.2V,

 

1

7

μA

ICCDR

 

 

 

 

VIN > VCC – 0.2V or VIN < 0.2V

 

 

 

 

tCDR [7]

Chip Deselect to Data

 

 

 

0

 

 

ns

 

 

Retention Time

 

 

 

 

 

 

 

t

[8]

Operation Recovery Time

 

 

 

t

 

 

ns

 

R

 

 

 

 

RC

 

 

 

Figure 3. Data Retention Waveform

 

 

VCC(min)

DATA RETENTION MODE

VCC(min)

V

CC

V

> 2.0V

 

tCDR

DR

 

tR

 

 

 

 

CE

 

 

 

 

Notes

7.Tested initially and after any design or process changes that may affect these parameters.

8.Full device operation requires linear VCC ramp from VDR to VCC(min) > 100 μs or stable at VCC(min) > 100 μs.

Document Number: 001-07970 Rev. *D

Page 4 of 11

[+] Feedback

Image 4
Contents Features Logic Block DiagramFunctional Description Cypress Semiconductor Corporation 198 Champion CourtPin Configuration Product PortfolioElectrical Characteristics Maximum RatingsOperating Range CapacitanceParameters Unit Data Retention CharacteristicsParameter Description Conditions Min Typ2 Max Unit Switching Characteristics Write CycleSwitching Waveforms Read Cycle No.1 Address Transition ControlledWrite Cycle No 1 WE Controlled 13, 17 Write Cycle 3 WE controlled, OE LOW Inputs/Outputs Mode Power Ordering InformationTruth Table BHE BLEPackage Diagrams Pin Tsop IIDocument History Issue Date Orig. Change Description of ChangeREV ECN no