Furuno DP-6 manual Enabling Timer Operation, Stopping Timer Operation

Page 55

5.8 Timer Operation

A built-in timer permits automatic transmission and reception of telex messages.

Enabling Timer Operation

1.Press function key [F3] to display the Operate menu.

2.Press the [7] key to display the Timer Operation List.

3.Select the operation (name) you wish to execute. Press the [En- ter] key. An asterisk appears beside the operation selected and "T. Op" appears in inverse video on the communication status display. If a file from a floppy disk is to be sent, be sure the floppy disk containing the file is inserted in the drive.

Timer Operation List

*1

2

3

OP4

OP5

Figure 5-10 Timer operation list

4.Select another operation (name) if desired.

5.Press the [Esc] key.

When the predetermined time comes, the DP-6 automatically sends or receives messages. The results of timer operation are displayed as either OK or NG (No Good) on the Timer Operation List.

Timer Operation List

*1

OK

2

 

*3

OK

*OP4

OK

*OP5

NG

Figure 5-11 Timer operation list

Stopping Timer Operation

1.Press function key [F3].

2.Press the [7] key.

3.Select the operation (name) which has asterisk attached to it and then press the [Enter] key. Remove all asterisks to cancel all timer programs.

5-11

Image 55
Contents Nbdp Terminal First E D I T I O N Page Page Table of Contents Declaration of conformity to type SP-1Foreword FeaturesProgram number This page is intentionally left blank Frequency Shift Radiotelex CommunicationGeneral Code DescriptionDescription ARQ Mode A-ModeTraffic Exchange Sequence Termination of Communication ARQ mode traffic exchange timingInitiating a Call FEC Mode B-ModeSystem Overview System ConfigurationEquipment Description Turning on the SystemTerminal Unit Printer option Main UnitKeyboard Menu Conventions Function Keys, Menu OperationBasic Menu Operation Clear Buffer Cancel PrintingFunction Key Description File to PrintGoto Top Function key F2 Edit menuRent file File to Send Cancel SendingTimer Operation Call StationDistress Frequency Table Display Nmea DataCalendar Remote A/BUser Channel Entry Timer Operation EntryStation Entry Scan EntryBK Timing PostTone SetupSlave Delay BK Timing PreToneTX/RX MSG Save Display modeMIF Freeze MIF EmissionFunction key F10 Break Function key F9 OverRegistering Answerback Code & ID Codes Preparations for Transmission and ReceptionRegistering Answerback Code Message for confirmation of code entered Registering ID CodesRegistering Stations Station ListEditing/Deleting Stations OK/CANCEL promptRegistering Timer Programs Timer ProgrammingEditing/Deleting Timer Programs Registering Scan Channel Groups Scan Channel GroupsEditing/Deleting Scan Channel Groups Registering User Channels User ChannelsEditing/Deleting User Channels Creating Files File OperationsSaving a File Saving a FileCutting and Pasting Text Editing FilesCutting text Select All Copying and Pasting TextClearing the Paste Buffer UndoSearching Text Cut and paste flow diagramGoto Line Replacing TextOpening Files Switching Between FilesOpening a File Saving a File Under a New Name Renaming FilesDeleting Files Printing Files Real Time PrintingDisplaying the Communications Log Log File Communications LogPrinting the Log File Manual Calling TRANSMISSION, ReceptionManual calling screen Calling a Station Stopping Transmission Transmitting a File from a Floppy Disk or the Text ScreenFrom a Floppy Disk From the text screen 1 orARQ Mode Operation Selecting Receive ModeSend a file from a floppy disk Type a message from keyboard FEC Mode OperationCommunication Example Registration procedure9VG Seradio RS 55908 Ugox X GA +? Transmitting message directly DirtlxTable of Abbreviations Command an AbbreviationEnabling Timer Operation Timer OperationStopping Timer Operation Communication Buffer ScanningWindow Menu Description Window MenuDisplay Nmea Data Remote A, Remote B CalendarDistress Frequency Table Maritex Operation What is MARITEX?Preparations for Transmission Maritex ServicesRegistering Scan Groups MARITEX-A Maritex Channel ARQ FEC Dirc Scanning group list example Preparing Programs for Automatic Message Transmission CommandsMaritex Traffic Manual Store-and-Forward Telex No. Procedure DisplayRemarks@CASE MSG+? @SEND Babc @SEND Nnnn @CASE GA+? @SEND BRK+ Preparing a macrofile for store-and-forward TelexSave prompt Example macrofile for direct dialing Macrofile for Direct DialingNo. Procedure Display Remarks Procedure for direct dialingExample of macrofile for use in multi address Macrofile for Multi Address10 Example of macrofile for semi-fax Macrofile for Semi-faxTransmitting in Maritex System Basic ProcedurePress the 2 key. The Call Macro screen appears Actual TransmissionConnectors and Earth Connection Maintenance and TroubleshootingMaintenance Cleaning the EquipmentSelf Test Simple TroubleshootingDiagnostic Tests Power SupplyTone test 1 All characters Tone TestTone test 5 Space Tone test 2 FoxTone test 3 Beta Tone test 4 MarkITU Telex Frequency /4 AP1-1AP1-2 AP1-3 AP1-4 AP2-1 Appendix 2 International Telex AbbreviationsThis page is intentionally left blank Load requirements as listner Input sentencesAP3-1 AP3-2 GLL Geographic position latitude and longitudeAP3-3 RMA Recommended minimum navigation information Loran C dataAP3-4 RMC Recommended minimum specific GPS/ Transit dataSpecifications of Nbdp Terminal DP-6 Environmental Conditions