Connect Tech BlueStorm Universal PCI DB-25 Male Pinouts for BlueStorm/LP 2 Port Connector

Page 13

BlueStorm Installation Guide, Connect Tech Inc.

the operating system is booted by the current driver/software RS-485 mode. The jumper is used to ensure that a port will power-on tri-stated. For example, the RS-485 mode selection in the Windows control panel will override this jumper setting once a port is opened.

The BlueStorm/LP RS-422/485 uses JC to configure Auto-485 mode, while the BlueStorm/SP Opto uses J1.

Note that on BlueStorm/LP RS-422/485 models the Auto 485 is a single jumper. The second site is not in use. See Figure 1 for the location of this jumper. On the BlueStom/SP Opto, the first position controls the first port pair, while the second position controls the second port pair.

Power-On Tri-state (BlueStorm/SP Models Only, Excludes BlueStorm/SP RJ-11)

BlueStorm/SP models offer a power-on tri-state similar to the Auto-485 mode listed above. The BlueStorm/SP will tri-state a port configured as RS-485 full duplex or RS-485 multi-drop slave. This is meant to ensure compatibility with our legacy Blue Heat/PCI cards for customers upgrading to the newer BlueStorm family.

Jumper J1 controls the power-on tri-state functionality. Install a jumper on the first location of the J1 in order to tri-state Port 1 at power-on, install a jumper on the second position of J1 to control Port 2, etc. Ports will not come out of tri-state until the driver opens the associated port and begins transmission.

Half Duplex and Multi-drop Slave modes require you to select the appropriate mode via software. Please refer to the readme.txt files found in the appropriate directories on the BlueStorm/LP/SP/SP Opto CD.

Connectors and Pinouts

Table 1: DB-25 Male Pinouts for BlueStorm/LP (2 Port Connector)

 

Pin

Port

RS-232

Signal

RS-422/485

Signal

 

 

No.

No.

Signal

Direction

Signal

Direction

 

 

1

2

SG

signal gnd.

SR

signal ref.

 

 

2

1

TXD

output

TXD-

output

 

 

3

1

RXD

input

TXD+

output

 

 

4

1

RTS

output

RTS-

output

 

 

5

1

CTS

input

RTS+

output

 

 

6

1

DSR

input

CTS-

input

 

 

7

1

SG

signal gnd.

SR

signal ref.

 

 

8

1

DCD

input

RXD+

input

 

 

9

2

TXD

output

TXD-

output

 

 

10

2

RXD

input

TXD+

output

 

 

11

2

RTS

output

RTS-

output

 

 

12

2

CTS

input

RTS+

output

 

 

13

2

DSR

input

CTS-

input

 

 

14

 

NC

no connect

NC

no connect

 

 

15

 

NC

no connect

NC

no connect

 

 

16

 

NC

no connect

NC

no connect

 

 

17

 

NC

no connect

NC

no connect

 

 

18

 

NC

no connect

NC

no connect

 

Revision 0.10

 

 

 

13

Image 13
Contents Contact Information BlueStorm Universal PCICopyright Notice Limited Lifetime WarrantyTrademark Acknowledgment Table of Contents List of Tables Contact Information Customer Support OverviewMail/Courier Email/InternetIntroduction FeaturesHardware Configuration BlueStorm Installation OverviewFull Duplex Mode Half Duplex ModeMulti-drop Slave Mode Jumper Block Diagrams for BlueStormLine Bias/Termination BlueStorm/LP Jumper Block Locations 2 Port Models BlueStorm/SP Jumper Block Locations 8 Port Models BlueStorm/SP RJ-11 8 Port Model Jumper Configuration for BlueStormTxD Control Pin Port RS-232 Signal RS-422/485 Direction DB-25 Male Pinouts for BlueStorm/LP 2 Port ConnectorHDB-44 Pinouts for BlueStorm/LP 4 Port Connector BlueStorm Installation Guide, Connect Tech Inc VHDCI-68 Female Pinouts for BlueStorm/LP 8 Port Connector VHDCI-68 Female Pinouts for BlueStorm/LP Pin Port Signal RS-422/48 232 Direction HDB-78 Pinouts for BlueStorm/SP 8 Port ConnectorInput RxD B+ No connect HDB-78 Pinouts for BlueStorm/SPRS-232 RS-422/485 Pin No Signal Direction RJ-45 Pinouts for BlueStorm/SP Opto 4 Port ConnectorPin # RS-232 RS-422/485 DB-9 DB-25 Signal Signal Direction CAG104K Technical Tip RJ-11 Pinouts for BlueStorm/SP RJ-11 Ports 7 and 8 OnlyBlueStorm External I/O Box Diagram RS-422/485 Wiring Diagrams BlueStorm/SP Opto Only Software/Driver Installation Hardware InstallationSpecifications Baud RatesUARTs Surge SuppressionVcci Certification