Connect Tech BlueStorm Technologies Installation Guide for Electronic Accessories

Page 27

BlueStorm Installation Guide, Connect Tech Inc.

Certification

Connect Tech Inc. declares that the product(s) covered by the contents of this manual have been tested and found compliant with the below listed standards as required by the Electromagnetic Compatibility (EMC) Directive for General Immunity Compliance, EN 50 0082.1:1997

EN 55022 Conducted and Radiated emissions

CISPR 22 Class A

EN 55024 Immunity to Disturbances

EN 61000-4-2 EN 61000-4-3

EN 61000-4-4 EN 61000-4-6

The above satisfy the requirements of:

USA:

FCC Class A 47CFR, Part 2

Canada:

ICES-003

Europe:

EMC Directive

Japan:

VCCI

Australia/New Zealand: AS/NZS

Industry Industrie Canada Canada

The above agency conformances were met by independent laboratory testing of Connect Tech Inc. product(s) with shielded cables, with metal hoods, attached to either the terminating connectors or cable assemblies supplied with the product(s). Failure to follow good EMC/EMI compliant cabling practices may produce more emissions or less immunity than were obtained in laboratory measurements.

Operation of this equipment in a residential area may cause unacceptable interference to radio and TV reception, requiring the user to take whatever steps necessary to correct the interference.

Revision 0.10

27

Image 27
Contents Contact Information BlueStorm Universal PCILimited Lifetime Warranty Copyright NoticeTrademark Acknowledgment Table of Contents List of Tables Email/Internet Customer Support OverviewContact Information Mail/CourierIntroduction FeaturesHalf Duplex Mode BlueStorm Installation OverviewHardware Configuration Full Duplex ModeJumper Block Diagrams for BlueStorm Multi-drop Slave ModeLine Bias/Termination BlueStorm/LP Jumper Block Locations 2 Port Models BlueStorm/SP Jumper Block Locations 8 Port Models BlueStorm/SP RJ-11 8 Port Model Jumper Configuration for BlueStormTxD Control Pin Port RS-232 Signal RS-422/485 Direction DB-25 Male Pinouts for BlueStorm/LP 2 Port ConnectorHDB-44 Pinouts for BlueStorm/LP 4 Port Connector BlueStorm Installation Guide, Connect Tech Inc VHDCI-68 Female Pinouts for BlueStorm/LP 8 Port Connector VHDCI-68 Female Pinouts for BlueStorm/LP Pin Port Signal RS-422/48 232 Direction HDB-78 Pinouts for BlueStorm/SP 8 Port ConnectorInput RxD B+ No connect HDB-78 Pinouts for BlueStorm/SPRS-232 RS-422/485 Pin No Signal Direction RJ-45 Pinouts for BlueStorm/SP Opto 4 Port ConnectorPin # RS-232 RS-422/485 DB-9 DB-25 Signal Signal Direction CAG104K Technical Tip RJ-11 Pinouts for BlueStorm/SP RJ-11 Ports 7 and 8 OnlyBlueStorm External I/O Box Diagram RS-422/485 Wiring Diagrams BlueStorm/SP Opto Only Baud Rates Hardware InstallationSoftware/Driver Installation SpecificationsUARTs Surge SuppressionVcci Certification