Connect Tech CTIM-00015, BlueStorm Universal PCI HDB-78 Pinouts for BlueStorm/SP 8 Port Connector

Page 18

BlueStorm Installation Guide, Connect Tech Inc.

Table 4: HDB-78 Pinouts for BlueStorm/SP (8 Port Connector)

Pin

Port

RS-

Signal

RS-422/48

Signal

No.

No.

232

Direction

5

Direction

 

 

Signal

 

Signal

 

1

5

RTS

output

RTS A(-)

output

2

5

CTS

input

RTS B(+)

output

3

5

DSR

input

CTS A(-)

input

4

5

RI

input

CTS B(+)

input

5

5

SG

signal gnd.

SR

signal ref.

6

6

RTS

output

RTS A(-)

output

7

6

CTS

input

RTS B(+)

output

8

6

DSR

input

CTS A(-)

input

9

6

RI

input

CTS B(+)

input

10

7

RTS

output

RTS A(-)

output

11

7

CTS

input

RTS B(+)

output

12

7

DSR

input

CTS A(-)

input

13

7

RI

input

CTS B(+)

input

14

7

SG

signal gnd.

SR

signal ref.

15

8

RTS

output

RTS A(-)

output

16

8

CTS

input

RTS B(+)

output

17

8

DSR

input

CTS A(-)

input

18

8

RI

input

CTS B(+)

input

19

 

NC

no connect

NC

no connect

20

 

NC

no connect

NC

no connect

21

5

TxD

output

TxD A(-)

output

22

5

RxD

input

TxD B(+)

output

23

5

DTR

output

RxD A(-)

input

24

5

DCD

input

RxD B(+)

input

25

6

SG

signal gnd.

SR

signal ref.

26

6

TxD

output

TxD A(-)

output

27

6

RxD

input

TxD B(+)

output

28

6

DTR

output

RxD A(-)

input

29

6

DCD

input

RxD B(+)

input

30

7

TxD

output

TxD A(-)

output

31

7

RxD

input

TxD B(+)

output

32

7

DTR

output

RxD A(-)

input

33

7

DCD

input

RxD B(+)

input

34

 

SG

signal gnd.

NC

no connect

35

8

TxD

output

TxD A(-)

output

36

8

RxD

input

TxD B(+)

output

37

8

DTR

output

RxD A(-)

input

38

8

DCD

input

RxD B(+)

input

39

8

SG

signal gnd.

SR

signal ref.

…Continued on next page

18

Revision 0.10

Image 18
Contents BlueStorm Universal PCI Contact InformationLimited Lifetime Warranty Copyright NoticeTrademark Acknowledgment Table of Contents List of Tables Mail/Courier Customer Support OverviewContact Information Email/InternetFeatures IntroductionFull Duplex Mode BlueStorm Installation OverviewHardware Configuration Half Duplex ModeJumper Block Diagrams for BlueStorm Multi-drop Slave ModeLine Bias/Termination BlueStorm/LP Jumper Block Locations 2 Port Models BlueStorm/SP Jumper Block Locations 8 Port Models Jumper Configuration for BlueStorm BlueStorm/SP RJ-11 8 Port ModelTxD Control DB-25 Male Pinouts for BlueStorm/LP 2 Port Connector Pin Port RS-232 Signal RS-422/485 DirectionHDB-44 Pinouts for BlueStorm/LP 4 Port Connector BlueStorm Installation Guide, Connect Tech Inc VHDCI-68 Female Pinouts for BlueStorm/LP 8 Port Connector VHDCI-68 Female Pinouts for BlueStorm/LP HDB-78 Pinouts for BlueStorm/SP 8 Port Connector Pin Port Signal RS-422/48 232 DirectionHDB-78 Pinouts for BlueStorm/SP Input RxD B+ No connectRJ-45 Pinouts for BlueStorm/SP Opto 4 Port Connector RS-232 RS-422/485 Pin No Signal DirectionPin # RS-232 RS-422/485 DB-9 DB-25 Signal Signal Direction RJ-11 Pinouts for BlueStorm/SP RJ-11 Ports 7 and 8 Only CAG104K Technical TipBlueStorm External I/O Box Diagram RS-422/485 Wiring Diagrams BlueStorm/SP Opto Only Specifications Hardware InstallationSoftware/Driver Installation Baud RatesSurge Suppression UARTsCertification Vcci