Connect Tech CTIM-00015, BlueStorm Universal PCI user manual Surge Suppression, UARTs

Page 26

BlueStorm Installation Guide, Connect Tech Inc.

UARTs

BlueStorm/LP (2 port models)

17D152 dual UART with 64 byte TxD/RxD FIFO buffers

BlueStorm/LP (4 port models)

17D154 quad UART with 64 byte TxD/RxD FIFO buffers

BlueStorm/LP (8 port models)

17D158 octal UART with 64 byte TxD/RxD FIFO buffers

BlueStorm/SP and BlueStorm/SP RJ-11 (8 port models)

17D158 octal UART with 64 byte TxD/RxD FIFO buffers

BlueStorm/SP Opto (2 and 4 port models)

17D152 dual UART(s) with 64 byte TxD/RxD FIFO buffers

Surge Suppression

BlueStorm/LP/SP/SP RJ-11 (excludes BlueStorm/SP Opto)

TransGuardTransient Voltage Suppression, able to withstand multiple strikes on every signal of every port

Transient Energy dissipation 0.05 joules on every signal of every port

Transient peak current rating 15A on every signal of every port

EN61000-4-2/3/4 compatible

Optical Isolation

BlueStorm/SP Opto

3kV peak to peak optical isolation on every signal of every port

Dimensions

BlueStorm/LP

Low profile form factor - MD1 compliant

BlueStorm/SP

 

Length:

11.991 cm, 4.721 inches

Height:

9.652 cm, 3.8 inches

BlueStorm/SP Opto

 

Length:

14.702 cm, 5.788 inches

Height:

10.605 cm, 4.175 inches

BlueStorm/SP RJ-11

 

Length:

12.129 cm, 4.775 inches

Height:

10.668 cm, 4.2 inches

26

Revision 0.10

Image 26
Contents BlueStorm Universal PCI Contact InformationTrademark Acknowledgment Limited Lifetime WarrantyCopyright Notice Table of Contents List of Tables Mail/Courier Customer Support OverviewContact Information Email/InternetFeatures IntroductionFull Duplex Mode BlueStorm Installation OverviewHardware Configuration Half Duplex ModeLine Bias/Termination Jumper Block Diagrams for BlueStormMulti-drop Slave Mode BlueStorm/LP Jumper Block Locations 2 Port Models BlueStorm/SP Jumper Block Locations 8 Port Models Jumper Configuration for BlueStorm BlueStorm/SP RJ-11 8 Port ModelTxD Control DB-25 Male Pinouts for BlueStorm/LP 2 Port Connector Pin Port RS-232 Signal RS-422/485 DirectionHDB-44 Pinouts for BlueStorm/LP 4 Port Connector BlueStorm Installation Guide, Connect Tech Inc VHDCI-68 Female Pinouts for BlueStorm/LP 8 Port Connector VHDCI-68 Female Pinouts for BlueStorm/LP HDB-78 Pinouts for BlueStorm/SP 8 Port Connector Pin Port Signal RS-422/48 232 DirectionHDB-78 Pinouts for BlueStorm/SP Input RxD B+ No connectRJ-45 Pinouts for BlueStorm/SP Opto 4 Port Connector RS-232 RS-422/485 Pin No Signal DirectionPin # RS-232 RS-422/485 DB-9 DB-25 Signal Signal Direction RJ-11 Pinouts for BlueStorm/SP RJ-11 Ports 7 and 8 Only CAG104K Technical TipBlueStorm External I/O Box Diagram RS-422/485 Wiring Diagrams BlueStorm/SP Opto Only Specifications Hardware InstallationSoftware/Driver Installation Baud RatesSurge Suppression UARTsCertification Vcci