INSTALLATION-WIRING DIAGRAMS SECTION 100-816-208

MARCH 1993

PDKU CONNECTOR

 

W-BL

 

26

1

 

 

 

BL-W

 

1

 

 

 

2

 

 

 

W-O

 

27

 

 

 

 

3

 

 

 

O-W

 

2

 

 

 

 

4

 

 

 

W-GN

 

28

 

 

 

 

5

 

 

 

GN-W

 

3

 

 

 

 

6

 

 

 

W-BR

 

29

 

 

 

 

7

 

 

 

BR-W

 

4

 

 

 

 

8

 

 

 

W-S

 

30

 

 

 

 

9

 

 

 

S-W

 

5

 

 

 

 

10

 

 

 

R-BL

 

31

 

 

 

 

11

 

 

 

BL-R

 

6

 

 

 

 

12

 

 

 

R-O

 

32

 

 

 

 

13

 

 

 

O-R

 

7

 

 

 

 

14

 

 

 

R-GN

 

33

 

CONNECTOR

 

 

15

 

GN-R

 

8

 

 

 

16

 

 

 

 

R-BR

 

34

 

 

 

 

17

 

 

 

BR-R

 

9

 

 

 

 

18

 

 

 

R-S

 

35

 

 

 

 

19

 

 

 

S-R

 

10

 

AMP

 

 

20

 

BK-BL

 

36

 

 

 

21

 

 

 

 

BL-BK

 

11

 

W/MALE

 

 

22

 

BK-O

 

37

 

 

 

 

23

 

 

 

O-BK

 

12

 

 

 

 

24

 

 

 

BK-GN

 

38

 

CABLE

 

 

25

 

GN-BK

 

13

 

 

 

26

 

 

 

 

BK-BR

 

39

 

PAIR-

 

 

27

 

 

 

 

 

BK-S

 

40

29

 

BR-BK

 

14

 

28

25

S-BK

 

15

 

30

 

 

 

 

 

 

 

 

Y-BL

 

41

 

 

 

 

31

 

 

 

BL-Y

 

16

 

 

 

 

32

 

 

 

 

 

 

 

BRIDGING

CLIPS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

STATION CABLING

 

JACKETED TWISTED PAIRS

(-)

T1 (VOICE/DATA)

 

24AWG (1 PAIR)

 

 

 

 

(GND)

R1 (VOICE/DATA)

 

 

 

PT1

(NOT USED)

 

 

 

RT2

 

 

 

 

 

 

 

 

T2

 

 

 

 

 

R2

 

DC OUTPUT

 

R

GN

PT2

CKT 2

 

 

 

 

 

 

PR2

 

AC/DC EXTERNAL

R1

T1

T3

 

BK

Y

R3

 

POWER SOURCE

 

 

PT3

CKT 3

 

 

W

BL

PR3

 

 

 

 

AC INPUT

 

 

 

T4

 

 

 

 

 

 

 

 

 

R4

 

 

 

6 5 4 3 2 1

PT4

CKT 4

TO 120 VAC

 

 

PR4

 

2 3 4 5

 

 

COMMERCIAL POWER

 

T5

 

TR

 

 

OUTLET

 

 

R5

 

 

 

2-PAIR

 

 

 

 

PT5

CKT 5

 

 

 

 

 

 

MOD CORD

PR5

 

 

RJ11

 

REQUIRED

T6

 

 

 

 

 

 

 

 

 

R6

 

 

 

 

 

PT6

CKT 6

 

 

 

 

PR6

 

 

 

 

 

T7

 

(-)

GND

 

 

R7

 

 

 

 

T

R

 

 

PT7

CKT 7

 

 

 

 

 

 

PR7

 

 

 

 

 

T8

 

 

 

 

 

R8

 

 

 

 

 

PT8

CKT 8

 

 

 

 

PR8

 

 

 

 

 

 

 

 

 

DIGITAL (1000 OR 2000 SERIES)

 

 

 

 

TELEPHONE

 

 

 

 

 

(WITH OR WITHOUT PDIU-DI/

 

 

 

 

PDIU-DI2)

 

 

 

 

 

-OR-

 

 

 

 

 

DDSS, DDCB, PDIU-DS

 

AC/DC EXTERNAL POWER SOURCE SPECIFICATIONS:

AC IN: 120 VDC ± 10%

DC OUT: 24 VDC ± 10%

160 MA (MIN.) DC CURRENT

200 MV P-P (MAX) AC RIPPLE ON DC OUTPUT

AC/DC power supplies that meet the above requirements are available from most telephone equipment supply houses.

EXTERNAL POWER STRAPS:

If the external power is installed, cut the external power straps located inside the digital telephone, DDSS, DDCB, or PDIU- DS.

See Table 8-Dat the front of this section for external power requirements.

FIGURE 8-28

DK16 EXTERNAL POWER FOR DIGITAL TELEPHONE CONNECTION

8-32

Page 226
Image 226
Toshiba DK 16, DK8 manual DK16 External Power for Digital Telephone Connection, AC/DC External Power Source Specifications