INSTALLATION-CONFIGURATION

SECTION 100-816-203

MARCH 1993

TABLE 3-A

DK8 CO LINE/STATION CONFIGURATION GUIDE

EQUIPMENT

KSU

=

Key Service Unit ·2 CO Lines/4 digital circuits) CO

=

Central Office

QCDU =

Optional PCB (1 CO line/2 digital circuits)

DKT

=

Digital Telephone

QSTU

=

Optional PCB (2 standard circuits)

 

SLT

=

Standard Telephone

 

 

 

 

 

 

 

 

 

 

CONFIGURATION CO

COs

DKTs

SLTs

 

EQUIPMENT

 

 

LINES BY STATION

 

 

 

 

 

2 by 4

2

4

 

KSU

 

 

 

 

 

 

2 by 6

2

4

2

KSU + QSTU

 

 

 

 

 

3 by 6

3

6

 

KSU + QCDU

 

 

 

 

 

3 by 8

3

6

2

KSU + QCDU + QSTU

 

 

 

 

4 by 8

4

8

 

KSU + QCDU + QCDU

 

 

 

 

4 by 10

4

8

2

KSU + QCDU + QCDU + QSTU

 

TABLE 3-B

DK16 CO LINE/STATION CONFIGURATION GUIDE (BASE AND EXPANSION UNIT)

EQUIPMENT

BU

=

Base Unit (4 CO lines/8 digital circuits)

PSTU =

EU option (8 standard circuits)

KSTU

=

Base Unit Option (4 standard circuits)

PCOU =

EU option (4 CO lines)

EU

=

Expansion Unit

 

 

CO

=

Central Office line

PDKU =

EU option (8 digital circuits)

 

DKT

=

Digital telephone

KCDU =

EU option (2 CO lines/4 digital circuits)

EKT

=

Electronic telephone

PEKU =

EU option (8 electronic circuits)

 

SLT

=

Standard telephone

PESU =

EU option (2 standard/4 electronic circuits)

 

 

 

 

 

 

 

 

 

 

 

 

CONFIGURATION CO

COs

DKTs

EKTs

SLTs

 

 

EQUIPMENT

LINES BY STATION

 

 

4 by 8

 

4

8

 

 

 

 

BU

4 by 12

 

4

8

 

4

 

 

BU + KSTU

4 by 14

 

4

8

4

2

 

 

BU + EU + PESU

4 by 16

 

4

8

 

8

 

 

BU + EU + PSTU

4 by 16

 

4

8

8

 

 

 

BU + EU + PEKU

4 by 16

 

4

16

 

 

 

 

BU + EU + PDKU

4 by 18

 

4

8

4

6

 

 

BU + KSTU + PESU

4 by 20

 

4

8

8

4

 

 

BU + KSTU + EU + PEKU

4 by 20

 

4

16

 

4

 

 

BU + KSTU + EU + PDKU

4 by 20

 

4

8

 

12

 

 

BU + KSTU + EU + PSTU

6 by 12

 

6

12

 

 

 

 

BU + EU + KCDU

6 by 16

 

6

12

 

4

 

 

BU + KSTU + EU + KCDU

8 by 8

 

8

8

 

 

 

 

BU + EU + PCOU

8 by 12

 

8

8

 

4

 

 

BU + KSTU + EU + PCOU

8 by 14

 

8

8

4

2

 

 

BU + EU + PCOU + PESU

8 by 16

 

8

8

8

 

 

 

BU + EU + PCOU + PEKU

8 by 16

 

8

16

 

 

 

 

BU + EU + PDKU + PCOU

8 by 16

 

8

16

 

 

 

 

BU + EU + KCDU + KCDU

8 by 18

 

8

8

4

6

 

 

BU + KSTU + EU + PCOU + PESU

8 by 20

 

8

16

 

4

 

 

BU + KSTU + EU + KCDU + KCDU

8 by 20

 

8

8

8

4

 

 

BU + KSTU + EU + PCOU + PEKU

8 by 20

 

8

16

 

4

 

 

BU + KSTU + EU + PCOU + PDKU

8 by 20

 

8

8

 

12

 

 

BU + KSTU + EU + PCOU + PSTU

3-2

Page 24
Image 24
Toshiba DK 16 manual DK8 CO LINE/STATION Configuration Guide