REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES

SECTION 100-816-600

MARCH 1993

TABLE RM-R

TYPE 2 PROGRAM PROCEDURE EXAMPLE

(PROGRAMS: 20, 30, 31, 35, 40, 41, 43, 79, 81 ~ 89)

STEP

 

ACTION

 

 

 

 

 

DISPLAY/PRINTOUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Enter Program Mode

 

 

>MODE PROG

 

At the >MODE prompt, enter P R O G CR.

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Enter Program Number

 

 

P 30

 

Refer to the record sheet and enter the desired program number.

 

 

 

 

 

 

 

 

 

 

 

 

Example: Program 30, enter 3 0, press CR.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Enter Port Number

or Port Range

*

P30

 

Refer to the System Record Sheet and enter the desired

P30 04

 

port number(s). Example: 0 4.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Press # button.

 

 

P30 04#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Enter the Desired Button/LED Number

 

P30 04# 01 N (Note)

 

Example: Button/LED 01, enter: 0 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

To Change Button/LED Status

 

P30 04# 01 N Y

 

Refer to the System Record Sheet and change the button/LED

 

 

 

 

 

 

 

 

 

 

 

 

status, if required (Y or N).

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: Enter Y.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

To Advance to Next Button/LED

 

 

 

 

 

 

 

 

 

 

 

 

 

Press SPACE (repeat Step 6 if necessary).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

To Review Button/LED Status Change

 

P30 04# 01 Y- LED "ON"

 

Press CR.

 

 

 

 

 

 

 

 

 

 

Button LED Number

 

 

 

 

 

 

 

 

 

 

 

Re-enter Steps 3, 4, and 5.

 

 

 

 

 

 

 

 

 

Port Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Program Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

To Exit Program/Store Data

 

P10

 

A) To store data, press CR.

 

P10 ##

 

B) To exit this program, press # #, then press CR.

P

 

C) Continue returning to Step 2 until all Type 2 programs

 

 

 

 

 

 

 

 

 

 

 

 

are completed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

To Exit the Program Mode

 

>MODE

 

Press # # CR.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

To Enter Another Mode,

 

 

 

 

 

 

 

 

 

 

 

 

 

Press

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D U M P CR

(data dump)

 

D

 

T E S T CR

(test)

 

T

 

M E S G CR (LCD messages)

 

(no prompt)

 

R E P T CR

(speed dial)

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

Y = button/LED(s) "ON", N = button/LED(s) "OFF"; U = button/LED(s) "ON" some ports and "OFF" other ports.