REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES

SECTION 100-816-600

MARCH 1993

TABLE RM-Q

TYPE 1 PROGRAM PROCEDURE EXAMPLE

(PROGRAMS: 10-1, 10-2, 10-3, 15, 16, 42-0, 77-1, 77-2)

STEP

 

ACTION

 

 

 

 

DISPLAY/PRINTOUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Enter Program Mode

 

>MODE PROG

 

 

 

 

 

At the >MODE prompt, enter P R O G CR.

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Enter Program Number

P 10

 

 

 

 

 

Refer to the record sheet and enter the desired program number.

P10

 

 

 

 

 

Example: Program 10-1, enter 1 0, press CR.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Enter Program Code or Digit(s) Per Record Sheet

P10 1

 

 

 

 

 

1 or other digit required.

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Most programs do not require a second digit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Enter Button/LED Number

P10 1 01 N

(see note)

 

Enter the desired button/LED number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: Button/LED 01, enter 0 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

To Change Button/LED Status

P10 1 01 N Y

 

Refer to the System Record Sheet and change the button/LED

 

 

 

 

 

 

 

 

 

 

 

 

status, if required (Y or N).

 

 

 

 

 

 

 

 

 

 

 

 

Example: Enter Y.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

To Advance to Next Button/LED

P10 1 01 Y

 

 

 

 

 

Press SPACE. Repeat step 5 if necessary.

 

 

 

 

02 N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

To Review Button/LED Status Change

P10 1 01 Y-

 

 

Button LED "ON"

 

Enter CR.

 

 

 

 

 

 

 

 

 

 

Button LED Number

 

 

 

 

 

 

 

 

 

 

 

Re-enter Steps 3 and 4.

 

 

 

 

 

 

 

 

 

 

Program Code

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: This step is optional and not required to save data.

 

 

 

 

 

 

 

 

 

Program Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

To Exit Program/Store Data

P10

 

 

 

 

 

A) To store data, press CR.

P10 ##

 

 

 

 

 

B) To exit this program, press # #, then press CR.

P

 

 

 

 

 

C) Continue returning to step 2 until all Type 1 programs

 

 

 

 

 

 

 

 

 

 

 

 

are completed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

To Exit the Program Mode

> MODE

 

 

 

 

 

Press # # CR.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

To Enter Another Mode

 

 

 

 

 

 

 

 

 

 

 

 

Press

 

 

 

 

 

 

 

 

 

 

 

 

 

D U M P CR (data dump)

D

 

 

 

 

 

T E S T CR

(test)

T

 

 

 

 

 

M E S G CR (LCD messages)

(no prompt)

 

 

 

 

 

R E P T CR

(speed dial)

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

Y = button/LED "ON", N = button/LED "OFF"

-26-

Page 276
Image 276
Toshiba DK 16, DK8 manual Table RM-Q Type 1 Program Procedure Example