3.35DK16 Expansion Unit MOH Relay Control. Configure the PIOU or PIOUS for the MOH relay function in accordance with the following steps (refer to Figures 7-6 and 7-7):

1)Access Program 77-1. Set LED 05 to ON to configure the Night/MOH relay for the MOH relay function.

2A) Set the P11 jumper plug on the PIOU to the

MAKE or BREAK position, as required:

MAKE—Shorts the normally open con- tacts (pins 9 and 34) when any CO line is on hold.

BREAK—Opens the normally closed contacts (pins 9 and 34) when any CO line is on hold.

2B) Solder the W2 jumper on the PIOUS to the

MAKE or BREAK position, as required:

MAKE—Shorts the normally open con- tacts (NHT and NHR) when any CO line is on hold.

BREAK—Opens the normally closed contacts (NHT and NHR) when any CO line is in on hold.

3)Refer to Figures 7-6 and 7-7 for wiring/inter- connecting details. Connect the PIOU or PIOUS to the MDF as required for the MOH relay function.

4EXTERNAL SPEAKER UNIT (HESB) OPTIONS

4.00STRATA DK8 and DK16 systems provide three options utilizing an HESB:

4.01DK8 and DK16 Loud Ringing Bell Option. The Loud Ringing Bell option allows the voice first or ringing signal tone to be amplified without the use of other manufacturers’ equipment. The voice first and ringing signal tones can be amplified on all 6500-series electronic telephones and 2000- and 1000-series digital telephones equipped with HHEU PCBs (refer to Section 100-816-206). The HESB automatically turns off once the ringing call or voice first has been manually answered from the elec- tronic or digital telephone. This turn-off feature prevents audio feedback problems.

4.02Amplified Speaker Option. The Amplified Speaker option allows the HESB to be configured as a paging speaker. The HESB is connected to the 600 ohm Page RCA jack on the DK8 KSU or DK16 Base Unit to provide an amplified external speaker.

4.03Talkback Amplified Speaker Option. The Talkback Amplified Speaker option allows a talkback speaker to be provided in areas where a telephone is not needed. In this configuration, the HESB is connected to the 600 ohm Page RCA jack on the DK8 KSU or DK16 Base Unit and is used as the amplifier and speaker. The door phone unit (MDFB) is connected to the HESB, and serves as a microphone to provide talkback operation. (The MDFB microphone is always on in this application so the pushbutton is inoperative, and the unit serves only as a microphone for talkback.)

NOTE:

The 600 ohm Page RCA jack is two-way (duplex) and is compatible with most commer- cially available talkback amplifiers.

4.10System Hardware Requirements

4.11System hardware requirements vary depend- ing on the HESB option selected. Refer to the following installation procedures for the system hardware requirements for each option.

4.20HESB Option Installation

4.21Loud Ringing Bell Installation. Install the HESB Loud Ringing Bell option in accordance with the following procedures:

DK8 and DK16 HESB Installation for Digital Telephone Loud Ring Bell (Figure 7-10):

1)Connect a jumper between Terminals 2 and 10 on the HESB TB1 terminal block.

2)Connect a jumper between Terminals 4 and 5 on the HESB TB2 terminal block.

NOTES:

1.HESB connections made in steps 3~5 may be accomplished using the HESB VOICE modular jack instead of the TB1 terminal block.

7-12

Page 144
Image 144
Toshiba DK 16, DK8 manual External Speaker Unit Hesb Options, System Hardware Requirements