INSTALLATION-WIRING DIAGRAMS

SECTION 100-816-208

MARCH 1993

TABLE 8-B

STATION LOOP REQUIREMENTS

Device Description

Max Loop Resistance

Max Distance from

Number of

(Including Device)

KSU to Device

Wire Pairs 1

Electronic4 telephone

40 ohms

1000 ft. (303 m)

2-pair. EKTs which

 

 

 

receive OCA calls

 

 

 

HDSS console

20 ohms

500 ft. (152 m)

need 3-pair.

 

 

 

 

Standard telephones,

 

Approx. 3000 ft. (909 m)

 

300 ohms

with 150 ohm device. See

 

voice mail,

1-pair

manufacturer's product

auto attendant, etc.

 

 

 

specifications for exact

 

 

 

 

 

 

resistance of device.

 

 

 

 

 

Digital telephone

 

 

1-pair4

or

40 ohms

1000 ft. (303 m)

DDCB3

 

 

 

DDSS console

40 ohms

1000 ft. (303 m)

1-pair4

 

 

 

 

PDIU-DI

40 ohms

1000 ft. (303 m)

Shares digital

PDIU-DI2

telephone wire-pair.4

 

 

 

 

PDIU-DS

40 ohms

1000 ft. (303 m)

1-pair 4

 

 

 

 

ADM

40 ohms

1000 ft. (303 m)

Shares digital

telephone wire-pair.4

 

 

 

 

NOTES:

1.Use 24 AWG twisted pairs.

2.PESU circuits 3 and 4 are not used.

3.DDCB can connect only to Circuit 5 of the DK16 Base Unit or Circuit 1 of the PDKU or KCDU.

4.Two-pair, larger wire, or local telephone power supply is required to achieve maximum range, see Table 8-D.

8-2

Page 196
Image 196