2)Connect the music source to the music ampli- fier input.

3)Connect the paging amplifier outputs to PIOU (PGIN) relays K1 ~ K4 and zone A ~ zone D speakers (C).

4)Connect the music amplifier (+) output to terminal 23 (PG COMMON) of the PIOU, and the (–) output to the “C” terminal of zone A ~ zone D speakers.

5)Connect zone A ~ zone D speakers “A” termi- nal to the “PGOUT” contact of the PIOU relays K1~ K4 respectively.

5.16DK16 Night Ringing over All External Page Zones (PIOU only). To allow the night ringing signal to be sent over zone paging, install the paging amplifier in accordance with the following steps (refer to Figure 7-18). (Steps 2 ~ 6 are performed at the MDF.)

IMPORTANT NOTE: To night ring over selected PAGE zone, see Paragraph 9 of this section.

1)Connect the amplifier input via an RJ11 jack to the J7 600 ohm Page RCA jack on the Base unit. Or, direct connect J7 to Amp using a standard audio cable with RCA plugs.

2)Cross-connect the amplifier output A to the PGIN1 ~ PGIN4 connector from the PIOU.

3)Cross-connect the amplifier output B to the zone A ~ zone D speaker common line.

4)Cross-connect the PIOU PGOUT1 ~ PGOUT4 to zone A ~ zone D speakers (A).

5)Cross-connect the amplifier output A to pin 9 (NHR) of the PIOU.

6)Cross-connect a jumper from pin 34 (NHT) to pin 23 (PG COMMON) from the PIOU PCB.

7)In Program 77-1, set LED 05 to OFF and 06 to ON. Set LED 08 to ON if door phones are to ring over external page when the system is in NIGHT mode.

INSTALLATION-PERIPHERALS

SECTION 100-816-207

MARCH 1993

8)In Program 78, enable the CO lines that are to ring via external page when the system is set in the NIGHT mode.

9)In Program 39, assign the Night Transfer 1 or Night Transfer 2 buttons to digital or electronic telephones per the System Record Sheets (see Note 2).

10)Press the Night Transfer 1 or Night Transfer 2 button on an electronic or digital telephone to set the system into the NIGHT mode. Test by calling into the system on a CO line assigned (Program 78) to night ring over external page.

When ringing sounds (see Note 2) over the page, press Intercom 5 3 5 to answer.

NOTES:

1.All zones will ring with this option; night ringing to selected zones is not possible; see paragraph 9 for night ring over se- lected page zones.

2.The Night Transfer 1 or Night Trans- fer 2 buttons put CO lines in NIGHT ring mode per Program 15; NT1-TENANT 1/ NT2-TENANT 2 CO line assignment.

6DK8 AND DK16 STATION MESSAGE DETAIL RECORDING (SMDR) PRINTER/ CALL ACCOUNTING DEVICE OPTIONS

6.00An SMDR printer or call accounting device may be connected to the system to provide a hard- copy record of station activity (incoming, outgoing, and transferred calls account code entries) on CO lines or a printout of the customer data base. Call record data is printed out at the completion of each call. Program SMDR with Program 60, and use Program 97 to have the SMDR printer display the customer data base.

6.01SMDR will send out special names for the following types of calls:

MSS: Prints on DISA calls to stations (see Note).

MODM: Prints on calls to the IMDU remote maintenance modem (station 619).

DISA: Prints on DISA calls to CO lines when

7-23