REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993

-21-

IMPORTANT NOTE:

This program clears Call Forward memory for all stations, but does not reset the Call Forward

indication on the station (Call Forward LCD information and/or Call Forward button/LED). To

clear station Call Forward indications, system power must be turned OFF for five seconds, then

ON. Fixed Call Forward is not cleared by this program.

TABLE RM-J
PROGRAM 92 (continued)CALL FORWARD BACKUP RAM INITIALIZATION
ACTIONSTEP DISPLAY/PRINTOUT
1>MODE PROGEnter Program Mode
At the >MODE prompt, enter P R O G CR.
2P 92
P92
Enter Program Number 92
Press CR.
3P92
P92 9
Enter 9.
4P92
P92 9 03 N
Enter button/LED number 0 3.
5P92
P92 9 03 N Y
Change LED 03 to "ON" by
entering Y.
7 Change LED 04 to "ON" by
entering Y.
8 Press CR.
Initialization complete.
6P92
P92 9 03 N Y
Press SPACE.
04 N
P92
P92 9 03 N Y
04 N Y
P92
P92 9 03 N Y
P92 04 N Y
NOTE: If program data is not entered correctly,
CR
will
not respond. To retry, press
DELETE CR
at the same time
.
9 To exit this program, press # # CR.